Message:
0405 – Drive motor fault
Right wheel is stuck
Possible cause:
– Overload at right drive wheel
Remedy:
– Clean robotic mower (
– Level out any uneven areas (holes,
depressions) in mowing area
Message:
0502 – Mowing motor fault
Temperature range exceeded
Possible cause:
– Temperature in mowing motor too high
Remedy:
– Allow robotic mower to cool down
Message:
0505 – Mowing motor fault
Mowing motor overloaded
Possible cause:
– Dirt between carrier plate and mowing
deck housing
– Mowing motor cannot be switched on
– Mowing motor overloaded
Remedy:
– Clean mowing blade and mowing deck
(
16.2)
Clean carrier plate (
16.6)
– Set higher cutting height (
– Level out any uneven areas (holes,
depressions) in the mowing area
78
Message:
0701 – Battery temperature
Outside temperature range
Possible cause:
– Temperature in battery too low or too
high
16.2)
Remedy:
– Allow robotic mower to warm up or cool
it down – observe permissible
temperature range of battery (
Message:
0703 – Battery discharged
Battery voltage too low
Possible cause:
– Battery voltage too low
Remedy:
– Place robotic mower in docking station
to recharge battery (
Message:
0704 – Battery discharged
Battery voltage too low
Possible cause:
– Battery voltage too low
Remedy:
– Place robotic mower in docking station
to recharge battery (
Message:
9.5)
1000 – Rollover
Allowed inclination exceeded
Possible cause:
– Tilt sensor has detected a rollover
Remedy:
– Place robotic mower on its wheels,
check for damage and confirm
message with OK
Message:
1010 – iMOW® raised
Press OK to release
Possible cause:
– Robotic mower has been lifted by hood
Remedy:
– Check movement of hood and confirm
message with OK
6.4)
Message:
1030 – Hood fault
Check hood
Then press OK
Possible cause:
– No hood detected
Remedy:
– Check hood (movement, firm seating)
and confirm the message with OK
15.7)
Message:
1105 – Flap open
Operation aborted
Possible cause:
– Flap open during automatic operation
– Flap open during automatic edge
following
Remedy:
15.7)
– Close the flap (
Message:
1120 – Hood blocked
Check hood
then press OK
Possible cause:
– Permanent collision detected
15.2)