Operation
This appliance is provided with an auto-evaporation feature for
condensate removal during air conditioning and
dehumidification mode.
Note: in case of high ambient humidity, it is possible to drain
the condensate continuously by applying the hose supplied to
the upper drainage hose ( Chapter 6.3.1 "Continuous
drainage", Page 93).
Fan mode
•
To correctly set this mode, press repeatedly the
until FAN appears on the display. To select the desired air
flow, press repeatedly the
flows are:
– Minimum air flow: for silent operation.
– Medium air flow: for a good balance between noise and
air flow.
– Maximum air flow: for maximum air flow.
•
The display will show the room temperature.
5.2.8 Swing function
This function moves the air outlet flap on the top panel up and
down to evenly distribute the air into the room. The function can
be activated in each mode.
•
Press the
button to enable the swing function. The air
outlet flap will begin to move up and down alternatively.
•
If the
button is pressed again, the flap will be locked into
its current position.
•
If the
button is pressed again, the flap will start to move
up and down again.
Note: in order to avoid damaging the internal mechanism, do
not move the flap manually!
90
button
button. The available air
5.2.9 Timer function
The timer allows the delayed start-up or shut-down of the
appliance.
Delayed start-up
While the appliance is in standby, delayed start up can be
programmed.
▶ Press the
button.
HOUR ON and 0.5 will be displayed.
▶ Press or hold the
or
numbers of hours (0.5 hour increments between 0.5 and
10h and 1 hour increments between 10h and 24h) to start-
up appear on the display.
▶ Press the
button again within 10 seconds to set the
timer.
If the
button is not pressed within 10 seconds, the
timer setting will be exited.
After the timer function is enabled, the display shows back
the time and the previously set settings. After the timer
function is enabled, the settings (Mode, Fan speed, Swing)
can be changed. Sleep mode cannot be selected.Once the
set time is elapsed, the appliance will start-up in the
previously set settings.
▶ To cancel the timer program, press the
Delayed shut-down
While the appliance is on in any operating mode, delayed shut
down can be programmed.
▶ Press the
button.
HOUR OFF and 0.5 will be displayed.
▶ Press or hold the
or
numbers of hours (0.5 hour increments between 0.5 and
10h and 1h increments between 10h and 24h) to shut-
down appear on the display.
▶ Press the "timer" button again (within 10 seconds) to set
the timer.If the
button is not pressed within 10 seconds,
the timer setting will be exited.
After the timer function is enabled, the display shows the
operating mode/settings and the timer symbol stays lit.
Once the set time is elapsed, the appliance goes into
standby.
▶ To cancel the timer program, press the
Cool 4000 – 6721858458 (2023/04)
button until the desired
button again.
button until the desired
button again.