Descargar Imprimir esta página

Dometic COOLAIR RTX1000 Instrucciones De Uso página 23

Equipo de aire acondicionado a motor parado
Ocultar thumbs Ver también para COOLAIR RTX1000:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 75
RTX1000/2000, SPX1200
8.2
Control panel fault messages
The "ERROR" symbol (fig. 4 5, page 5) lights up if there is a fault with the parking
cooler. The type of error is shown on the display by the following error codes:
Display
Description
text
F01
The compressor does not
work.
F02
F03
F04
The condensor fan 1 does
not work.
F05
The condensor fan 1 is
overloaded.
F06
The condensor fan 2 does
not work.
F07
The condensor fan 2 is
overloaded.
F08
The evaporator fan does
not work.
F09
The evaporator fan is
overloaded.
F10
The condensation water
that has formed is not
being discharged.
F11
The system cannot
determine the internal
temperature.
F12
EN
Cause
Error in compressor sensor
electrical supply (open
circuit).
Error in compressor sensor
electrical supply (short
circuit).
Compressor overload
No response from the fan.
Faulty fan speed
No response from the fan.
Faulty fan speed
No response from the fan.
Faulty fan speed
The condensation water
that has formed is not being
discharged.
Error in temperature sensor
electrical supply (open
circuit).
Error in temperature sensor
electrical supply (short
circuit).
Display messages
Remedy
➤ Switch off the system.
➤ Switch it on again after
30 min.
➤ If the fault occurs again,
contact an authorized
workshop.
23
loading

Este manual también es adecuado para:

Coolair rtx2000Coolair spx1200tcCoolair spx1200ic