RTX1000/2000, SPX1200
7.2
Switching on the parking cooler
A
NOTICE! Damage hazard
Never close all of the air nozzles of the parking cooler simultaneously.
The system would ice up inside.
I
NOTE
The first time the parking cooler is used, there may be a slight smell. This
odor is caused by a design feature and ends after the system has been
running for a short time.
➤ With the system switched off, press the
✔ The fan starts.
✔ The Power LED (fig. 2 7, page 4) lights up.
✔ The digital display (fig. 2 1, page 4) shows the current status of the parking
cooler (see chapter "Display" on page 12).
I
NOTE
Depending on the system status, the system compressor is switched on
with a delay of up to 180 s.
7.3
Switching the parking cooler to standby mode
➤ Press the
button briefly to switch the parking cooler to standby mode.
✔ The parking cooler saves the current settings.
✔ The Power LED (fig. 2 7, page 4) continues to light up.
I
NOTE
• When the parking cooler is in BOOST mode and switched to
standby mode, it will start the next time in AUTO mode.
• A running timer is set to 0 by switching the parking cooler in standby
mode.
• The parking cooler switches off completely after 12 hours in standby
mode to save power.
• SPX1200T, SPX1200C only: When the parking cooler is switched
to standby mode via remote control, an automatic pump cycle of 8 s
is started.
EN
Using the parking cooler
button.
15