Installation
Safety and Regulatory Compliance
The Bose FreeSpace FS2C loudspeaker has passed testing and complies with the following specifications and uses:
Listed to ANSI/UL 1480-2016, CAN/ULC-S541
Fire Protective Signaling Use – UL Category UUMW/UUMW7, File Number S 3241. Control Number 42S9.
Not for use with DC-supervised systems.
Suitable for use indoors in dry locations.
EN 54-24: 2008, Loudspeaker for Voice Alarm Systems for Fire Detection and Fire Alarm Systems for Buildings
Environmental: Type A (indoor applications)
Suitable for installation using Class 1, Class 2, or Class 3 wiring methods in accordance with NFPA 70, National Electric Code, 2002,
Article 640.
Suitable for use with fire alarm circuit wiring methods in accordance with NFPA 70, National Electric Code, 2002, Article 760
Suitable for use in air handling plenum spaces.
UL-2043, Fire Test and Visible Smoke Release for Discrete Products and their Accessories Installed in Air Handling Spaces.
NFPA 70, National Electric Code, 2002, Article 300-22 (c).
NFPA 90-A, 2002, Installation of Air Conditioning and Ventilation Systems, Paragraph 4.3.10.2.6.5.
EMC Directive 89/336/EEC and Article 10 (1) of the directive, EN50081-1 and EN50082-1 as signified by the CE mark.
The FreeSpace FS2C loudspeaker has been designed to the requirements defined in the following European regulatory specification for
combination systems:
British Standard Code of Practice BS 5839, Part 8, when used with the ceramic terminal block and thermal fuse.
Tested to IEC60268-5.
Nominal Coverage Angle (per UL 1480) Vertical: 145°/25° at –3 dB; 170°/5° at –6 dB
UL Sensitivity Wattage Tap Sound Pressure Level dBA at 3.1 meters (10 feet):
Wattage
CAN/ULC-S541
Canada
Tap
70 V
100 V
1 W
77.3 dBA
2 W
80.0 dBA
79.8 dBA
4 W
82.4 dBA
82.6 dBA
8 W
84.8 dBA
84.6 dBA
16 W
86.7 dBA
86.3 dBA
16 Ω
86.0 dBA
SPLs given are per the UL 1480 specified reporting method.
Frequency response:
Fire alarm (UL): 95 Hz to 17000 Hz
8 • English
Horizontal: 140°/20° at –3 dB; 170°/5° at –6 dB
Wattage
ANSI/UL 1480-2016
Tap
70 V
1 W
71.9 dBA
2 W
74.5 dBA
4 W
77.2 dBA
8 W
79.8 dBA
16 W
82.1 dBA
16 Ω
82.6 dBA
United States
100 V
74.9 dBA
77.5 dBA
79.9 dBA
82.2 dBA
Loudspeaker for voice alarm systems for fire detection and fire
2531
Bose Corporation
100 The Mountain Rd, Framingham, MA 01701
20
DOP 434849-6
EN 54-24: 2008
alarm systems for buildings
FreeSpace FS2C
Provided options:
Type A
For DOP 434849-6, see pro.Bose.com/FS2CDOP_UK
FreeSpace FS2C • Installation Guide
PRO.BOSE.COM