Drain Cock Conical Seal - Angelo Po 1N1Pi1G Manual De Uso

Marmita indirecta “gas”
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Use and installation
This drain cock can be used only for discharging
alimentary liquids or liquids for the production
of foodstuff .
Maintenance
It's advisable to perform cleaning and mainte-
nance operations after every use.
Do not use toxic or harmful chemicals.
Perform maintenance and cleaning observing
the following instructions.
Open and close the cock to verify that there in
1)
no more liquid upstream.
Extract the male (2).
2)
Clean all the parts, it is essential to grease the
3)
conical part.
Reinsert the male (2) inside the body (1)and
4)
adjust it in closing posotion.
Extraction and insertion of the male
Take the drain cock to the open position (1).
1)
Take the drain cock to the out position (5)
2)
throught a "S" motion (2-3-4).
Unstring the male (6). To insert the male put
3)
the screw in the slit (6).
5
3320160_ut_GB_rev.1

DRAIN COCK CONICAL SEAL

1
2
Take the drain cock to the out position (5).
4)
Take the drain cock to the open position (1)
5)
throught a "S" motion (7).
Attention: do not turn off the screw (see spa-
re part. n. 4 ).
3
- 13 -
7
4
6
GB