Electrical Connection - Angelo Po 1N1Pi1G Manual De Uso

Marmita indirecta “gas”
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Important
Importante
The equipment comes with a cable to con-
nect it to the outlet of the disconnecting
switch. If it is necessary to change the cable,
proceed as described below.
Important
Importante
The connection must be made by authorised,
skilled personnel, in accordance with the rel-
evant legal requirements, using appropriate
and specifi ed materials. The appliance is sup-
plied with operating voltage 230V/1N.
Caution - Warning
Before doing any work, cut off the mains
electricity supply.
Connect the appliance to the mains electricity
supply as follows:
GB
A
3320160_inst_GB_rev.1

ELECTRICAL CONNECTION

If not already present, install a circuit-breaker
1)
(A) with overload cutout and diff erential
safety breaker close to the appliance.
Open the hatch (B).
2)
Undo the screws (C) to remove the lid (D).
3)
Connect the circuit-breaker (A) to the termi-
4)
nal board (E) of the appliance as shown in the
diagram and in the electrical system diagram
at the back of the manual:
Use a fl exible cable with at least type H07RN-F
characteristics, rated for an operating tempera-
ture of at least 80°C.
When connecting, take care to connect the
neutral and earth lines.
Restore the initial conditions after completing
5)
the operation.
B
- 12 -
Important
Importante
D
C
E
ENGLISH
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

1t1pi1g1n1pi2g1t1pi2g1n1pi1ga1t1pi1ga1n1pi2ga

Tabla de contenido