4.4 TROUBLESHOOTING
Before requesting repair, conduct the following inspection.
If the problem persists, stop the use immediately.
Bring it to your dealer.
Abnormality at Work
Problem
The tool does not operate.
(The control panel displays
an error.)
After the tool stopped
automatically by the torque
control function, it won't
operate promptly even if
you pull the trigger switch.
The tool does not operate.
(The battery indication
lamp blinks.)
You cannot operate the
tool even if you press
the button on the control
panel.
(No display on the control
panel lights up.)
The display on the control
panel is not correct.
You hear a stop sound
when you turn off the
trigger switch.
EN
Possible cause
See ERROR CODES.
Refer to 4.3.1
Retightening prevention is
functioning.
Communication is taking a long
time.
Auto power-off is functioning.
(The battery pack level is
running low.)
There are some foreign bodies
on the contacts between the
battery pack and the tool.
Just after a battery pack is
attached, or you have operated
nothing for 5 minutes or more.
No work is done after a battery
pack is attached.
The battery pack has run out.
The battery pack is out of
order.
It is under the influence of
electromagnetic waves near a
high-voltage cable etc.
Operating noise of brakes.
- 105 -
Action
See ERROR CODES.
Refer to 4.3.1
This is not a failure.
If the communicating state
lasts longer, reconsider the
communication environment.
Pull out the battery pack.
Check the setting (radio field
intensity) of the controller.
<Read the Operating
Instructions of CE. >
Charge the battery pack.
Remove the foreign bodies.
Pull the trigger switch.
Charge the battery pack.
Replace the battery pack with a
new one.
This is not a failure.
However, do not use the tool,
because its electronic circuit
may malfunction, resulting in
unexpected operation.
This is not a failure.
Continued to the next page