Table "TAB1"
DESCRIPTION
Internal exchanger overtemperature (HTI)
External exchanger overtemperature (HTE)
External temperature probe failure (short
circuit) (TFS7)
External temperature probe failure (open
circuit) (TFS8)
Internal fan malfunction (SV)
Insufficient exchanger temperature (CF/RL)
Condensation water maximum level (OF)
EEprom parameters not valid (CKS)
Ambient temperature probe failure (short
circuit) (TFS1)
Ambient temperature probe failure (open
circuit) (TFS2)
Internal exchanger temperature probe fail-
ure (short circuit) (TFS3)
Internal exchanger temperature probe fail-
ure (short circuit) (TFS4)
External exchanger temperature probe
failure (short circuit) (TFS5)
External exchanger temperature probe
failure (open circuit) (TFS6)
ON: led on
-
OFF: led off
-
*: Flashing
LED D
LED C
LED B
green
yellow
green
OFF
OFF
ON *
OFF
OFF
ON *
OFF
ON *
OFF
OFF
OFF
OFF
OFF
ON *
OFF
OFF
ON *
ON *
OFF
ON *
ON *
ON *
OFF
OFF
ON *
OFF
ON *
ON *
OFF
ON *
ON *
ON *
OFF
ON *
ON *
OFF
ON *
ON *
ON *
ON *
ON *
ON *
LED A
red
OFF
ON *
OFF
ON *
ON *
OFF
ON *
OFF
OFF
ON *
OFF
ON *
OFF
ON *
EN - 39