c. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit
and the wall. Get it out after finish piping (Fig.8).
d. Push the lower part of the Indoor Unit up to the wall, Then move the Indoor Unit from side to side, up
and down to check if it is hooked securely.

4 - WATER PIPE INSTALLATION

4.1 - MATERIAL AND DIMENSIONS OF THE PIPES

Material of the pipes
Model
Coiled connection (flat plate)

4.2 - JOINING THE PIPES

Connection of the water pipe should be done by professionals.
Double-span should be used when connecting pipes of In-door Unit.
For the hydraulic connection of the conditions fitted with butterfly valve,
consult the relative installation instructions.
The use of a flexible hose for hy-
draulic connection is advised.
At the first debugging, completely expel
air from coils via expelling valve (S)
(fig.9).
5 -

ELECTRICAL CONNECTION

5.1 - PRELIMINARY OPERATIONS

Before proceeding with the electrical connection, it is necessary to remove the front panel of the appliance.
Disconnect the earth cable before removing the front panel.
Before carrying out any electrical connection, make sure that power supply is disconnected by the
units and that the systems to which the equipment must connect are compliant with the current
standards.
In case you want to proceed with installation without plug, proceed as described below:
- Use a screened cable with a minimum section of 0,5 mm
- Use a ground cable at least 20 mm longer than the active wires.
- Connect the ground connection wires to the corresponding terminal.
- Pull the wires to make sure they are connected correctly, then stop them with the specific cable tie.
For correct dimensioning of the guards, please refer to voltage and current consumption indicated on the
label located on the unit.
To access the board, remove the screws (12a) and the panel (12b) of the terminal box (12) (Fig.11).
The appliance connection MUST respect the European and national standards and MUST be
protected by a 30 mA differential switch.
Copper pipe
SLW 1000
SLW 1200
1/2"
F
3-way valve
Exhaust valve
(4 doors)
Connector
and a max length of 20 metres
2
Bi2 WALL AR 1000 - 1200 - 1400
SLW 1400
1/2"
1/2"
E
EN - 11