Parameter - Quality Espresso GAGGIA G6+ Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7.2 TECHNICAL PERSONNEL MENU
7.2.3 – PARAMETER
When pressed, we modify the
value. 120ºC...121ºC...., etc.
-The upper row is to programme the temperature
of each group.
- The lower row is to calibrate the temperature
probes, if necessary.
Probe adjustment group 1
Probe adjustment group 2
Probe adjustment group 3
Probe adjustment group 4
When pressed, we
modify the value.
90ºC...91ºC...., etc.
- Programming the maximum safety times,
the hot water times for teas, indication
mode (lighting of the button panels) and
the machine's installation date.
Safety time after which the
right steam will automatically
stop.
To modify the lighting mode of
the buttons, refer to section 5,
page 9, to change this via the
buttons.
Press to modify the value.
The upper row is used to programme the temperatures of the water / steam
-
boiler and the temperature at which the left and right steam probes cut out.
- The lower row is used to calibrate the temperature probes, only if necessary.
Press to select the value
to be changed.
Only for Grouptronic machines
40
Water / steam boiler temperature
Left steam cut out temperature
Right steam cut out temperature
W / S Boiler probe calibration
Right steam probe calibration
Left steam probe calibration
NEXT SCREEN
Temperature group 1 (left)
Temperature group 2
Temperature group 3
Temperature group 4
Press to select the group, or
the probe to be changed.
NEXT SCREEN
Safety time after which the left
steam will automatically stop.
Programmed time for hot water
for teas.
Section for inserting the
installation date.
Press to select.
NEXT SCREEN
GB

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Gaggia v6+

Tabla de contenido