Alarm, Warning And Function Messages - Quality Espresso GAGGIA G6+ Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.

Alarm, warning and function messages.

The machine's messages will be displayed in a different format depending on the type of message. We can differentiate
between 3 types of messages.
ALARM MESSAGES
Relating to the operation of a component within the machine.
WARNING MESSAGES
Indicating the need for perform a procedure, which has previously been programmed such as cleaning, regeneration, etc.
FUNCTION MESSAGES
Indicating that the machine is performing a specific function or is carrying out one of the machine's specific functions.
MESSAGES
E01-FLOWMETER ERROR 1
E02-FLOWMETER ERROR 2
E02-FLOWMETER ERROR 3
E02-FLOWMETER ERROR 4
E05-CONTINUOUS TIMEOUT 1
E06-CONTINUOUS TIMEOUT 2
E07-CONTINUOUS TIMEOUT 3
E08-CONTINUOUS TIMEOUT 4
E09-SECURITY LEVEL -
SWITCH OFF MAIN WATER TAP.
E10-NO WATER REFILL –
TURN GENERAL SWITCH OFF
E11-OVERHEATING –
CALL TECHNICAL SERVICE
W12-REGENERATE WATER SOFTENER
W13-CLEAN GROUPS
W14-DOSE TOO LARGE GROUP 1
W15- DOSE TOO LARGE GROUP 2
ACTIONS TO BE TAKEN
Contact Technical Service. This message is also indicated by
pushbutton panel 1 flashing.
Contact Technical Service. This message is also indicated by
pushbutton panel 2 flashing.
Contact Technical Service. This message is also indicated by
pushbutton panel 3 flashing.
Contact Technical Service. This message is also indicated by
pushbutton panel 1 flashing
This alarm appears when coffee is made on group 1 continuously for over 5
minutes.
This alarm appears when coffee is made on group 2 continuously for over 5
minutes.
This alarm appears when coffee is made on group 3 continuously
for over 5 minutes.
This alarm appears when making coffee with the group 4 continuously
for over 5 minutes.
Close the water inlet tap and notify technical service. This alarm warns us
that the water safety level in the boiler has been exceeded. Indicated by
all programmable coffee buttons flashing and the icon indicating the water level in
the boiler accompanied by an acoustic warning. After three consecutive warnings
from the hot water solenoid, this will open to avoid the water boiler from being
flooded. Coffee can only be made using the continuous coffee buttons.
Turn the general switch and notify the technical service.
This alarm warns that the level probe is not detecting any water in the boiler.
Indicated by the flashing programmable coffee buttons and icon indicating the water
level in the water boiler. Coffee can only be made using the continuous coffee
buttons.
Disconnect the general switch and notify the technical service.
Regenerate the softener or replace the filter with a new one and reset the Machine's
counter following the instructions in the Display's programming manual, refer to
page 37 - section 7.1.2
Carry out the automatic group cleaning, refer to page 32 - Section 4.2
For programming cleaning after a certain number of coffees, (refer to Technical
personnel menu - Parameterisation 4/7)
Dose programming in group 1 is too large, exceeding the maximum number of
Impulses.
Dose programming in group 2 is too large, exceeding the maximum number of
Impulses.W16-DOSIS TOO LARGE GROUP 3