Quick Guide
Installation
1. Attach the full assembly, or parts of it, to the wall
either with a DIN rail or by using wall screws and
plugs.
If the controller is installed inside a metal cabinet,
then locate the antenna outside the cabinet.
2. Connect the antenna to the controller using the
supplied antenna cable (0.5 – 5m, CAT5e/CAT6).
3. Connect the actuators.
4. Check that all wiring is complete and correct:
•
Actuators
•
Heating/cooling switch
•
Circulation pump
5. Ensure that the 230 V AC compartment of the
controller is closed and the fi xing screw is tightened.
6. Connect optional external sensor (compatible
thermostats only).
7. Set DIP switch on public thermostat T-163.
Function*
Standard room thermostat
Standard room thermostat together with a
fl oor temperature sensor
Standard room thermostat, or system device,
together with an outdoor temperature sensor
System device together with a supply
temperature sensor for heating/cooling
switch over function
System device where the sensor input is used
for Comfort/ECO switch over function
Remote sensor
System device where the sensor input is used
for heating/cooling switch-over function
* The thermostat can only be registered as a system device to a
Wave system with multiple controllers, if it is registered to the
master controller.
U P O N O R S M AT R I X WAV E · Q U I C K G U I D E
QUICK GUIDE
Switch
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
ON DIP
1 2 3 4
8. Insert batteries into the thermostats.
9. Select thermostat control mode (settings menu 04,
in digital thermostats only). Default: RT (standard
room thermostat).
10. Connect the power cable to a 230 V AC wall socket,
or if required by local regulations, to a junction box.
Register thermostats, the interface and other system
devices, in that order (next page).