UK
Register multiple controllers
CZ
Up to four controllers can be registered to an interface.
All additional controllers in the system must be
registered to the interface.
DE
N O T E !
At least one thermostat must be registered to
DK
the additional controller before registering to
the interface.
EE
See steps 15 and 16 in the "Register thermostat and/
or system device to a controller" section for more
information.
ES
Unregister one channel or system device
When a channel or system device is inaccurately
FI
registered or if a thermostat registration needs to be
redone, it is possible to remove the current registration
FR
from the controller.
N O T E !
HR
The controller must be unregistered in the
interface as well. Go to menu Main menu >
Preferences > RF Link and unregister.
HU
To unregister a channel:
1. Enter registration mode. Channel 1 LED fl ashes red/
IT
green, or the fi rst unregistered channel fl ashes red.
2. If a system device (interface etc) is to be
unregistered, enter system channel registration
LT
mode. The power LED fl ashes according to the
pattern long blink, short pause, long blink and
channel 1 LED fl ashes red/green.
LV
3. Use buttons < or > to move the pointer (LED
fl ashes red) to the selected channel (fl ashes green if
NL
registered) to unregister.
4. Press the < and > buttons simultaneously until the
NO
LED for the selected channel starts fl ashing red
(about 5 seconds).
PL
PT
RO
RU
SE
SI
SK
1 2
QUICK GUIDE
Unregister all channels
When one or more channels (thermostats and system
devices) are inaccurately registered, it is possible to
remove all registrations at the same time.
To cancel all channel registrations:
1. Enter registration mode. Channel 1 LED fl ashes red/
green, or the fi rst unregistered channel fl ashes red.
2. Press the < and > buttons simultaneously until the
LEDs for all channels except one turn off (about
10 seconds). The one remaining fl ashes red.
Room bypass
To reach the bypass settings, the controller must be
registered to the interface.
1. In the interface, go to the Room bypass menu,
Main menu > System settings > Room bypass.
2. Select a controller.
3. Select up to a maximum of two rooms.
4. Press the Confi rm button to save and exit the
menu.
Other functions
See full manual for more information about
Autobalancing of actuators (eliminating the need
of manual balancing,on by default), Heat pump
integration, Cooling, Comfort/ECO settings, Smart
Home Gateway, Room check, and Supply check etc.
N O T E !
The controller must be unregistered in the
interface as well. Go to menu Main menu >
Preferences > RF Link and unregister.
U P O N O R S M AT R I X WAV E · Q U I C K G U I D E