Electrical Connection - GE UVC7300SLSS Manual Del Propietario E Instalación

Campanas de inserción estándares
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ELECTRICAL CONNECTION

1. Remove the electrical junction box cover.
2. Remove the electrical box knockout.
Electrical Box
Knockout with
Strain Relief
3. Feed the Power Supply Cable through the hole
and secure with a strain relief.
4. Attach the white lead of the power supply (A) to
the white lead of the range hood (D) with a wire
nut. Attach the black lead of the power supply (B)
to the black lead of the range hood (C) with a wire
nut. Connect the house ground wire under the
green grounding screw (E).
House Wiring
B
C
Hood Wiring
5. Reattach the electrical junction box cover.
49-2000893 Rev. 3
Installation
E
A
D
15