Extraction Device Control Elements; Technical Data; Ambient Temperature; Relative Humidity - Abicor Binzel Xfume Power 350 Manual De Instrucciones Original

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4 Product description

4.3.2 Extraction device control elements

Fig. 5
A Service LED
B <Running delay> knob
C Fuse
F
E
D
Power LED
Service LED
<Running delay> knob
<Torch selection> knob

4.4 Technical data

Tab. 2

Ambient temperature

Relative humidity

Tab. 3
Ambient temperature
(operation, storage in a closed
environment)
Relative humidity
Installation height above sea level
Max. tilt angle
EN - 16
Extraction device control elements
C
The power LED lights up solid green if there are no faults. In the event of
a fault, the power LED goes off.
The service LED lights up solidly if the filter is full/clogged. Once the filter
has been changed, the LED goes out 10 seconds after the welding
process has been restarted.
The knob can be used to set the motor run-on time for the extraction
function to between 0% and 100% (depending on the arc time).
Turning the knob to the far right to the <On> position permanently
switches on the extraction function.
The volume flow on the extraction torch is monitored. As the threshold
varies depending on the torch type, the knob must be used to select the
currently connected extraction torch. If the lower limit for the permissible
value is breached, the power LED goes out and the acoustic signal
generator sounds.
<a>
<b>
<c>
<d>
<e>
<f>
Ambient conditions for transport and storage
Ambient conditions for operation
D Acoustic signal generator
E <Torch selection> knob
F Power LED
A
B
®
xFume
COMPACT
®
xFume
PRO 36
−20°C to +55°C
Up to 50% at +40°C
Up to 90% at +20°C
−10°C to +40°C
Up to 50% at +40°C
Up to 90% at +20°C
Max. 1,000 m
10°