Replace The Uv Lamp; About The Uv Lamp; Removing A Used Uv Lamp - Boneco P370 Manual De Instrucciones

Ocultar thumbs Ver también para P370:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 116

REPLACE THE UV LAMP

ABOUT THE UV LAMP

The UV lamp is a consumable and must be replaced
after a certain amount of time. The BONECO P370 has
an internal timer. After an operating time of 12,000
hours, the appliance alerts you to the upcoming
lamp change with the UV warning on the display:
If you continue to use the spent UV lamp for a
longer time, the effectiveness of the disinfec-
tion will decrease significantly.
Only touch the new UV lamp at the ends.
Touching the glass tube can shorten the ser-
vice life.

REMOVING A USED UV LAMP

1. Disconnect the BONECO P370 from the power out-
let.
2. Open the rear cover.
3. Wait 5 minutes and let the used UV lamp cool
down.
4. Remove the filter.
5. Unscrew the four screws to remove the cover of
the UV lamp.
6. Simultaneously hold both ends of the used UV
lamp and rotate them clockwise until the lamp
can be removed.