Electrical Connection - REMS Multi-Push S Instrucciones De Servicio

Ocultar thumbs Ver también para Multi-Push S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
eng
pressure test with compressed air and water, without accessories
REMS V-Jet TW, disinfection unit
REMS V-Jet H, cleaning and preservation unit
Printer
Paper roll, pack of 5
Case with inserts for printer
REMS Peroxi Color, dosing solution for disinfection
REMS CleanH, cleaner for heating systems
REMS NoCor, corrosion protection for heating systems
Test strips 0 – 1000 mg/l H
Test strips 0 – 50 mg/l H
2
for pressure testing with water (REMS Multi-Push SLW)
Pneumatic hose Ø 8 mm, 1.5 m long, with quick couplings NW 5
Connecting hose compressor/water connections with 1" hose
with air (REMS Multi-Push SL/SLW)
Compressed air hose pneumatic tools, 1.5 m long,
with quick couplings NW 7.2, for connecting pneumatic tools
Compressed air hose Ø 8 mm, 7 m long, with quick coupling
with compressed air (REMS Multi-Push SL/SLW)
Compressed air hose Ø 8 mm, 1.5 m long, with quick coupling
DN 5 (plug, socket) for gas testing with compressed air
(REMS Multi-Push SL/SLW)
High-pressure hose Ø ½", 7 m long, with
with caps, for pressure testing of pipe systems and vessels
with water (REMS Multi-Push SLW)
1" double nipple, for connecting 2 suction/pressure hoses
Caps 1" with chain (REMS Multi-Push)
Plugs 1" with chain (suction/pressure hoses)
Plugs ½" with chain (REMS Multi-Push SL/SLW)
Caps ½" with chain (high-pressure hose)
Pressure gauge 6 MPa/60 bar /870 psi
Fine scaled pressure gauge 1.6 MPa/16 bar/232 psi,
Fine scaled pressure gauge 250 hPa/250 mbar/3.6 psi,
REMS CleanM
1.3 Applications
D
Water temperature
Ambient temperature
pH value
Smallest test volume
Compressor
Compressor
Oil separation rate
Compressed air vessel volume (Fig. 1 (35))
Flushing of pipe systems
Flushing of pipe systems
Flushing water connections
Pressure testing of drinking water installations
Pressure testing
f drinking water installations (REMS Multi-Push SL/SLW)
P
Reading accuracy < 200 mbar
Reading accuracy
Pressure testing of gas installations (REMS Multi-Push SL/SLW)
Pressure testing of gas installations
Pressure te
Reading accuracy < 200 mbar
1.4 Electrical/electronic data
Type of protection terminal box
Type of protection device, motor
Protection class
Operating mode (continuous operation)
Screen (LCD)
Resolution
Data transfer with USB stick
Printer, battery
Charger printer
22
O
pack of 100
2
2,
O
pack of 100
2,
5°C – 35°C (41 °F – 95 °F)
5°C – 40°C (41 °F – 104 °F)
(REMS Multi-Push SL/SLW)
1 hPa/1 mbar/0.015 psi
0.02 MPa/0.2 bar/3 psi
(REMS Multi-Push SL/SLW)
10 Pa/0,1 mbar/0.002 psi
230 V~; 50 Hz; 1,500 W
110 V~; 50 Hz; 1,500 W
NiMH 6 V – ---; 800 mAh
Input
100 – 240 V~; 50 – 60 Hz; 0.15 A
Output
1.5 D
115601
Paper roll printer B × Ø
115602
1.6 Weight
115612
REMS Multi-Push S
115604
REMS Multi-Push SL
090015
REMS Multi-Push SLW
115703
115605
115607
Work place-related
115608
Emission value
091072
091073
2 Start-up
CAUTION
CAUTION
Transport weights above 35 kg must be carried by at least 2 persons.
115634
115637
Compressed air line compressor/pressure vessel (47) gets hot and can cause
burns if touched.
NOTICE
NOTICE
115618
REMS Multi-Push is not intended/suitable for permanent connection to the
installation. Disconnect all hoses from the installation after completing the work.
115621
REMS Multi-Push may not be operated unattended.

2.1 Electrical connection

115667
WARNING
WARNING
Caution: Mains voltage present!
115747
pressure testing unit, check whether the voltage given on the rating plate corre-
sponds to the mains voltage. Only use sockets/extension leads with a functioning
PE contact. The function of the PRCD fault current circuit breaker (Fig. 1 (1))
115661
must be checked every time before start-up and before beginning work:
045159
1. Plug the mains plug into the socket.
2. Press the RESET button (2), the PRCD control lamp (Fig. 1 (39)) lights red
(operating state).
115619
3. Pull out the mains plug, the PRCD control lamp (39) must go out.
115620
4. Plug the mains plug back into the socket.
115624
5. Press the RESET button (2), the PRCD control lamp (39) lights red (oper-
115623
ating state).
115140
6. Press the TEST button (3), the PRCD control lamp (39) must go out.
115045
7. Press the RESET button (2) again, the PRCD control lamp (39) lights red.
047069
The control lamp (Fig. 2 (5)) lights green. REMS Multi-Push is ready for
140119
operation after about 10 s.
WARNING
WARNING
If the described functions of the PRCD fault current circuit breaker (Fig. 1 (1))
The PRCD fault current circuit breaker tests the connected device, not the
6,5 – 9,5
installation before the socket nor interconnected extension leads or cable reels.
approx. 10 l
On building sites, in a wet environment, indoors and outdoors or under similar
unit on the mains with a fault current protection switch (FI switch) which interrupts
oil-free
the power supply as soon as the leakage current to earth exceeds 30 mA for
200 ms. A cable cross-section that corresponds to the power of the electronic
4.9 l
Press the On/Off button on the input and control unit's operating panel (Fig. 2
DN 25, 1"
(4)) for approx. 2 s, then release it. REMS Multi-Push is switched on and the
compressor switches on. The screen (6) is illuminated and the Logo REMS
Multi-Push logo appears followed by the Start menu:
, 2"
REMS Multi-Push S:
Flushing
Ingredients
Memory Manager
The screen display contains a maximum 5 lines with 20 characters each. Lines
with defaults or test values are displayed
ical formula symbols, a uniform verbal abbreviation and the value of the test
criterion in the sub-routines. These have the following meanings:
p refer
bar xxx
p refer
mbar xxx
p actual bar xxx
IP 44
p actual mbar xxx
IP 20
p diff
bar xxx
I
p diff
mbar xxx
S 1
t stabi
min xxx
3.0"
t test
min xxx
128 × 64 pixels
USB port
P+M
p H
O
bar
5 V – ---; 680 mA
2
v H
2
t H
2
570 × 370 × 530 mm (22.4" × 14.6" × 20.9")
L
= 73 dB(A); L
= 73 dB(A); L = 92 dB(A); K = ± 1 dB(A)
= 73 dB(A); L
PA
PA
PA
WA
REMS Multi-Push SL/SLW:
Flushing
Ingredients
Testing
Compressed Air Pump
Memory Manager
reference test pressure
bar
reference test pressure
mbar
actual test pressure
bar
actual test pressure
mbar
differential test pressure bar
differential test pressure mbar
stabilisation/wait time
min
test time
min
load test plastic + metal
water pressure
eng
32.0 kg (71 lb)
36.7 kg (81 lb)
39.0 kg (86 lb)
with phys-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Multi-push slMulti-push slw

Tabla de contenido