• TUBE SEAL
In order to maintain a watertight seal between the
tube and bell, inspect the seal for wear and replace
it if necessary.
• SEAL RING
The seal ring can be lubricated using a suitable food
grade grease. In order to maintain a watertight
seal, check the seal ring for wear and replace it if
necessary.
• WHISKS
The per formance of the whisks depends on
the condition of the wires. The metal wires may
become worn over time. In order to ensure optimum
performance, they will need to be replaced. Do not
use a defective or damaged whisk!
• CARTRIDGE
You need to change the cartridge :
- If liquid starts seeping into the foot
- If there is any play in the blade
1) Cartridge dismantling :
Position the knife dismantling tool
cartridge
. Remove the cartridge from its place
B
by knocking
on the knife dismantling tool
D
with a plastic mallet.
10
2) Cartridge mounting :
• THE POWER MIXER DOES NOT START.
1. Did you follow the previous operating instructions ?
(See section-Operating The Power Mixer).
2. Is the machine too hot ? Allow the power mixer
on the
C
to cool. Then retry.
C
3. Pull the plug and try another outlet.
4. Check outlet for current (breaker or fuse).
5. Call local Robot Coupe authorized ser vice
agency.
• THE POWER MIXER STOPS DURING (WHILE)
PROCESSING.
See the section On Operating the Power Mixer.
- The first paragraph describes the overload
protection. It may be necessary to allow the
machine to cool for up to 30 minutes before
restarting.
Direct the ears of
cartridge
in order
B
to be aligned with
the groove of the bell
. Push the cartridge
A
with the hand in the
direction of arrow,
then clip on into the
bell thanks to the knife
dismantling tool.
TROUBLE SHOOTING
If you cannot locate the cause of the problem
- Release the control button (CB).
- Unplug the power mixer.
- Are the blades free to rotate in the bell ?
- Is the drive shaft free to rotate ? To check
this, unplug the power mixer, remove the bell
and test the rotation of the end of the drive shaft
manually.
Check the condition of the plug and the power
cord.
• THE POWER MIXER STARTS TO SMELL HOT
OR SMOKE
- Turn the power mixer off and unplug it.
- Call your local authorized service agency.
• OVERLOAD WARNING LIGHT
(Only for MP 600 Turbo)
In case of overload or
FLASH
use of the mixer in a too
sticky preparation, the
intensity warning flashes
for 5 seconds to inform
you that the motor will
stop shortly. This stop
indicates that the prepa-
MP 600
ration in process is too
Turbo
thick or can not be made
with a stick blender.
In this case, you can still restart your mixer.
However, your machine will stop again if the consis-
tency of the preparation is not modified.