R134a/R456a TANK CELL

1
Disconnect the machine from the electrical supply.
Procure a known reference weight from 20 kg.
Remove
the rear plastic (ref 1, Fig.50) cover to
access the machine bottles.
Unscrew the R134a/R456a bottle lock nuts (ref 3b,
FIG. 50
Fig.51).
Separate the heating coil (ref 2b, Fig.51) from the
tank (do not touch or disconnect the wires of the resistance coil).