Installation, Maintenance, and Repair Manual
Series 825YA, LF825YA
Reduced Pressure Zone Assemblies
" – 2"
3
4
WARNING
!
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
WARNING
!
!
Local building or plumbing codes may require modifications
to the information provided. You are required to consult the
local building and plumbing codes prior to installation. If
the information provided here is not consistent with local
building or plumbing codes, the local codes should be
followed. This product must be installed by a licensed
contractor in accordance with local codes and ordinances.
!
!
WARNING
Need for Periodic Inspection/Maintenance: This product
must be tested periodically in compliance with local codes,
but at least once per year or more as service conditions
warrant. All products must be retested once maintenance
has been performed. Corrosive water conditions and/or
unauthorized adjustments or repair could render the product
ineffective for the service intended. Regular checking and
cleaning of the product's internal and external components
helps assure maximum life and proper product function.
LF825YA-FS
Series 825YA and LF825YA each include a flood sensor on the
relief valve to detect excessive discharge and trigger notification
of a potential flood event.
NOTICE
An add-on connection kit is required to activate the flood
sensor. Without the connection kit, the flood sensor is a passive
component and has no communication with any other device.
(A retrofit sensor connection kit is also available for existing
installations. See "Add-on and Retrofit Sensor Connection Kits,"
for ordering details.)
NOTICE
Use of the flood sensor does not replace the need to comply
with all required instructions, codes, and regulations related to
installation, operation, and maintenance of this product, including
the need to provide proper drainage in the event of a discharge.
Watts
is not responsible for the failure of alerts due to
®
connectivity or power issues.
RP/IS-F-825YA
Tabla de contenido
loading

Resumen de contenidos para Watts Febco 825YA Serie

  • Página 9: Ensambles De Zona De Presión Reducida

    Watts no asume responsabilidad por fallas de las alertas debido ® a problemas de conectividad o de alimentación.
  • Página 10 Pautas de instalación • Consulte los códigos locales para conocer los requisitos y Figura 2 Figura 1 restricciones específicas de instalación correspondientes a su área. FEBCO recomienda que la presión de suministro del sistema sea de un mínimo de 20 psi (138 kPa). •...
  • Página 11: Servicio Y Mantenimiento

    Servicio y mantenimiento Antes de realizar uno o ambos procedimientos, cierre la válvula de cierre de salida, y luego cierre la válvula de cierre de entrada. Purgue la presión residual del ensamble abriendo las válvulas de prueba No 4, No 3 y No 2; en ese orden. Además, realice los siguientes pasos.
  • Página 12 NO SER RENUNCIADA, INCLUYENDO LAS GARANTÍAS IMPLÍCITAS DE COMERCIABILIDAD E IDONEIDAD PARA UN PROPÓSITO PARTICULAR, TIENE UNA DURACIÓN LIMITADA A UN AÑO A PARTIR DE LA FECHA DE ENVÍO ORIGINAL. EE. UU.: T: (800) 767-1234 • F: (800) 788-4491 • FEBCOonline.com Canadá: T: (888) 208-8927 • F: (905) 481-2316 • FEBCOonline.ca Latinoamérica: T: (52) 55-4122-0138 • FEBCOonline.com RP/IS-F-825YA 2321 980025 © 2023 Watts...

Este manual también es adecuado para:

Febco lf825ya serieFebco lf825ya-fs

Tabla de contenido