Installation Manual of Room Air Conditioner
Preparation
Necessary Tools for Installation
Driver
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HFC free refrigerant R410A
more than 5cm
more than
10cm
Arrangement of piping
directions
Rear left
Rear
Left
right
Right
Below
more than 10cm
The marks from
to
A
in the figure are the
G
parts numbers.
The distance between
the indoor unit and the
floor should be more
than 2m.
more than 60cm
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual
NO.0010531115
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
Attention must be paid to
the rising up of drain hose
more than 10cm
more than
10cm
Selection of Installation Place
Indoor Unit
Place, robust not causing vibration, where the body can be supported sufficiently.
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent lamps in the room are lightened.
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked
G
F
Floor fixing dimensions of the
A
outdoor unit (Unit:mm)
C
Fixing of outdoor unit
D
E
more than15cm
is available as illustrated in the above figure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Fix the unit to concrete or block
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, fix the unit by attaching a
vibration-proof mat.

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Haier HSU-07HVA103/R2(DB)

  • Página 5: Preparación

    Manual de instalación de aparato de aire acondicionado Preparación Herramientas necesarias para realizar la instalación Selección del lugar de instalación Unidad interior Destornillador Llave dinamométrica (17 mm, 22 mm, 26 mm) ● Coloque la unidad sobre una superficie que pueda soportarla correctamente y no Alicate provoque vibraciones.
  • Página 6: Unidad Interior

    [Izquierda • Entubación trasera izquierda] Accesorios En caso de realizar la entubación por el lado izquierdo, corte con una cuchilla la cubierta de la entubación izquierda. En caso de realizar la entubación a través de la parte trasera izquierda, doble los Control remoto (1) Manguera de drenaje (1) tubos de acuerdo con la dirección de entubación que figura en la marca del orificio...
  • Página 7: Unidad Exterior

    Al conectar el cable, confirme el número de terminales de las unidades interior 4. Después de la instalación, el enchufe de alimentación debe encontrarse ubicado en Nota y exterior detenidamente. Si el cableado no se ha realizado correctamente no un lugar fácilmente accesible. se podrá...
  • Página 8: Durante El Drenaje

    1. Retire el tapón del puerto de mantenimiento de la válvula de 3 vías, el tapón del ● Después de insertar la tuerca cónica deberá procederse a realizar los trabajos de vástago de la válvula de 2 vías y 3 vías, y conecte el puerto de mantenimiento a conicidad.

Tabla de contenido