Enerpac CLL Instrucciones
Enerpac CLL Instrucciones

Enerpac CLL Instrucciones

Cilindros de gran tonelaje presión máxima 700 bar [10.000 psi]
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17

Enlaces rápidos

EIS 67.116-1
05/2015
index:
English Instruction Sheet (GB) ..................................................................................... page ................... 1-4
Français Notice d'Emploi (FR) ...................................................................................... page ................... 5-8
Deutsch Bedienungsanleitung (DE) ............................................................................. seite .................. 9-12
Italiano Manuale Istruzioni (IT) ..................................................................................... pagina ............ 13-16
Español Instrucciones (ES) ........................................................................................... página ............ 17-20
Nederlands Gebruikershandleiding (NL) ...................................................................... pagina ............ 21-24
Svenska Instruktionsblad (SV) ...................................................................................... sida ................ 25-28
Φύλλο οδηγιών στα Ελληνικά (GR) ............................................................................... Σελίδα ............ 29-32
Folha de Instruções - Português (PT) .......................................................................... página ............ 33-36
1.0 IMPORTANT RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage.
Shipping damage is not covered by warranty. If
shipping damage is found notify carrier at once. The
carrier is responsible for all repair and replacement
costs resulting from damage in shipment.
safety first
Read all instructions, warnings and cautions carefully.
Follow all safety precautions to avoid personal
injury or property damage during system operation.
Enerpac cannot be responsible for damage or
injury resulting from unsafe product use, lack of
maintenance or incorrect product and/or system
operation. Contact Enerpac when in doubt as to the
safety precautions and applications.
TO PROTECT YOUR WARRANTY, USE ONLY
ENERPAC HYDRAULIC OIL.
2.0 PRODUCT DESCRIPTION
2.1 CLL-cylinders
Single-acting, load return cylinders with an overflow
oilport for stroke restriction. CLL cylinders are
provided with a fully threaded plunger and a safety
lock nut for positive loadholding operations. CLL
cylinders DO NOT have a stopring. If mounting holes
are drilled in the cylinder bottom these are metric.
2.2 CLS cylinders
Single-acting, load return cylinders with an overflow
oilport for stroke restriction. CLS cylinders DO NOT
have a stopring. If mounting holes are drilled in the
cylinder bottom these are metric.
Rev. H
Instruction Sheet
CLL, CLR and CLS
High Tonnage Cylinders
maximum pressure 700 bar [10.000 psi]
2.3 CLR cylinders
Double-acting, hydraulic return cylinders with a
safety valve in the retract side to prevent accidental
over pressurization. If mounting holes are drilled in
the cylinder bottom these are metric.
3.0 GENERAL SAFETY ISSUES
Failure to comply with following cautions and warnings
could cause equipment damage or personal injury.
WARNING: CLL and CLS cylinders are
NOT equipped with a stopring to retain
the plunger. To prevent plunger over -
extension, a port is provided to vent the oil
out of the cylinder as the plunger reaches the maximum
stroke. When the RED LINE around the plunger
becomes visible, the plunger is at maximum extension.
Further extension could result in the plunger being
forced out of the cylinder. See illustration 1 below.
illustration 1 - CLL and CLS cylinders
RED LINE
Plunger shown at maximum extension
Lock Nut
CLL only
Plunger Travel
Restriction Port
Tabla de contenido
loading

Resumen de contenidos para Enerpac CLL

  • Página 4 NOTES:...
  • Página 8 NOTES:...
  • Página 12 NOTES:...
  • Página 16 NOTES:...
  • Página 17: Instrucciones Importantes De Entrega

    2.1 Cilindros CLL. Cilindros de simple efecto, con pistón retorno por gravedad, con un rebosadero de aceite para la limitación de la carrera. Los cilindros CLL van provistos de un pistón roscado y una tuerca Embolo en su extensión máxima de seguridad para lograr un posicionamiento y una retención de la carga correctos.
  • Página 18: Cargas Laterales

    El escape CLL y CLS son cilindros de retorno por gravedad. Se de fluido hidráulico apresión tiene furza precisa una fuerza de carga considerable para hacer suficiente para penetrar la piel, causando lesiones retrocer por completo el pistón.
  • Página 19: Para Quitar El Aire

    • Cambie el aceite hidráulico tal como se recomienda problema que requiera servicio o mantenimiento. en la hoja de instrucciones de la bomba. Enerpac ofrece kits de piezas de repuesto listos para usar para reparaciones o reemplazos. Póngase en 8.0 SOLUCION DE PROBLEMAS contacto con Enerpac.
  • Página 20 NOTES:...
  • Página 24 NOTES:...
  • Página 28 NOTES:...
  • Página 36 www.enerpac.com...

Este manual también es adecuado para:

ClrCls

Tabla de contenido