Operating Instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.
Speedaire
Compressors
For Warranty & Service 1-888-606-5587
Do Not Return To Branch
Description
Air compressor units are intended to provide compressed air to power pneumatic
tools, operate spray guns and supply air for pneumatic valves and actuators. The
pumps supplied with these units have oil lubricated bearings. A small amount of oil
carryover is present in the compressed air stream. Applications requiring air free of
oil vapor should have the appropriate filter installed. The air compressor units are to
be mounted per the instructions provided on a solid floor. Any other use of these
units will void the warranty and the manufacturer will not be responsible for prob-
lems or damages resulting from such misuse. Refer to the enclosed "Replacement
Parts Manual" to identify compressor as single stage or two-stage.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROB-
LEMS. To help recognize this informa-
tion, observe the following symbols.
Danger indicates
an imminently haz-
ardous situation which, if not avoided,
will result in death or serious injury.
Warning indicates
a potentially haz-
ardous situation which, if not avoided,
could result in death or serious injury.
Caution indicates a
potentially haz-
ardous situation which, if not avoided,
MAY result in minor or moderate
injury.
Notice indicates
important informa-
tion, that if not followed, may cause
damage to equipment.
Unpacking
After unpacking the unit, inspect care-
fully for any damage that may have
occurred during transit. Make sure to
tighten fittings, bolts, etc., before
putting unit into service.
Do not operate
unit if damaged
Form 5S5996
Air
®
during shipping, handling or use.
Damage may result in bursting and
cause injury or property damage.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or its
power cord may
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
GENERAL SAFETY
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure pump-
ing system, the following safety pre-
cautions must be observed at all times:
1. Read all manuals
included with this
product carefully.
Be thoroughly
familiar with the
controls and the proper use of
the equipment.
2. Follow all local electrical and safety
codes as well as the United States
National Electrical Codes (NEC) and
Occupational Safety and Health Act
(OSHA).
Printed in U.S.A.
02433
0508/138/VCPVP
Cast Iron Series
Breathable Air Warning
This compressor/pump is NOT
equipped and should NOT be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, you must fit
the air compressor/pump with suit-
able in-line safety and alarm equip-
ment. This additional equipment is
necessary to properly filter and puri-
fy the air to meet minimal specifica-
tions for Grade D breathing as
described in Compressed Gas
Association Commodity
Specification G 7.1 - 1966, OSHA 29
CFR 1910. 134, and/or Canadian
Standards Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line safety
and alarm equipment is not simulta-
neously used, existing warranties
are void, and Dayton Electric Mfg.
Co. disclaims any liability whatsoev-
er for any loss, personal injury or
damage.
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
MANUAL
4. Keep visitors away and NEVER allow
children in the work area.
5. Wear safety glasses and use
hearing protection when operating
the unit.
6. Do not stand on or use the unit as
a handhold.
7. Before each use, inspect compressed
air system and electrical compo-
IN250003AV 5/08
E
N
G
L
I
S
H
E
S
P
A
Ñ
O
L
F
R
A
N
Ç
A
I
S

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Speedaire Cast Iron Serie

  • Página 9: Descripción

    Protéjase Ud. y a los demás observando todas las reglas de seguridad. El no seguir las instrucciones podría resultar en heridas y/o daños a su propiedad. Guarde este manual como referencia. Compresores de aire Speedaire ® Por garantía y servicio 1-888-606-5587...
  • Página 10: Precauciones Para Rociar

    Manual de instrucciones de Speedaire Compresores de aire Speedaire ® residuos en el compresor. Informaciones Generales de enfriamiento interno no protege el sis- Seguridad (Continuación) tema. 19. Al rociar o limpiar con solventes o La presión máxima químicos tóxicos, siga las instrucciones es 12,07 bar en los del fabricante de dichos químicos.
  • Página 11: Serie De Hierro Colado

    Manual de instrucciones de Speedaire Serie De Hierro Colado TAMAÑO MÍNIMO DE LAS TUBERÍAS Instalación (Continuación) Para conectar las tuberías al tanque, util- DE LAS LÍNEAS DE AIRE COMPRIMIDO ice conexiones del mismo tamaño que el los pernos excesivamente. Debe per- orificio de salida.
  • Página 12: Tamaño Mínimo Del Alambre Use Alambres De Cobre De 75°C

    Manual de instrucciones de Speedaire Compresores de aire Speedaire ® Instalación (Continuación) Cabezal Acceso a la válvula de seguridad Pump Safety Valve Access usar los cables adecuados y de que: Tuyau flexible de Motor Discharge Motor refoulement 1. El amperaje sea adecuado.
  • Página 13: Lubricacion

    R56HZ, Y56Y ó L143T. Vea la placa LUBRICACION do para los compresores de aire del motor Speedaire. Use aceite 10W30 100% sin- ESTA UNIDAD NO Funcionamiento tético como por ejemplo Mobil 1 (Nº de TIENE ACEITE. Antes (Continuación)
  • Página 14: Funcionamiento Continuo

    Manual de instrucciones de Speedaire Compresores de aire Speedaire ® IMPORTANTE: Cámbiele el aceite mantenimiento. Funcionamiento (Continuación) Para mantener el funcionamiento efi- después de 50 horas de operación. tuerca de bronce y desconecte con ciente del sistema del compresor, cuidado el codo de la bomba de aceite.
  • Página 15: Guía De Diagnóstico De Averías

    Manual de instrucciones de Speedaire Serie De Hierro Colado tanque, para evitar que la unidad se Mantenimiento (Continuación) Polea del motor Volante mueva sin previo aviso. FILTRO DE AIRE Chequée la tensión de las bandas cada 3 Nunca utilice el cabezal del compresor meses.
  • Página 16 Manual de instrucciones de Speedaire Serie De Hierro Colado Compresores de aire Speedaire ® Guía de diagnóstico de averías (Continuación) Problema Posible(s) Causa(s) Acción a tomar Hace mucho ruido al 1. La polea, el volante, la banda, la tapa de las 1.

Tabla de contenido