13.2
PROBLEM SOLVING
Before of every Authorized Technician intervention, the same Technician has the duty
to check if the parameters of the mother board correspond to those of the table you
own.
In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized
Technician on order to avoi irreparable damages!
PROBLEM
CAUSE
The stove is
without power
supply
Burned board
protection fuse
Burned
protection fuse
in the electric
The control
socket
display does not
switch on
Faulty control
display
Faulty flat cable
Faulty electronic
board
Empty hopper
Auger blocked
by a foreign
object (for
Pellets do not
example nails)
reach the
combustion
The auger
chamber
geared motor is
out of order
Check if on the
display there
is an "ACTIVE
ALARM"
RONDÓ - MIKA
SOLUTION
Check if the plug is connected.
Replace the protection fuse in the board (4A-250V)
Replace the protection fuses in the electric socket
(3.15A-250V).
Replace the control display.
Replace the flat cable.
Replace the mother board.
Full the hopper.
Clean the auger.
Replace the geared motor.
Have the stove checked.
EN
INTERVENTION
85