If you want to cancel the setting temperature,
press "
" key to choose the heating " I " or
" II ", the product will work without setting
temperature. While the display "°C" will go off.
After continuous heating for 12 hours, the cool
fan will work for 30 seconds and enter into
standby mode.
SET WEEKLY PROGRAM
(ONLY by remote control)
After complete setting of current TIME/DAY, below
is the steps to set weekly program:
1) Press " ", the product enter into working
status.
2) Press "P", lighted "P", it enter into weekly
program setting: See below: A
3) Press "DAY", the display shows d1~d7, set to
working day (Monday-Sunday: d1~d7). Such as
set Monday: see below: B
4) Press "EDIT", the display shows P1~P6 (for each
day, it can be set maximum 6 time periods).
Such as setting P1: see below: C
5) Press "TIME/on", the display shows 00"as
default. Press "TIME/on"" continuously to
set the turn-on time. Such as set the turn-on
time 7:00am (Memo: the setting time 0-24 for
choice) see below: D
6) Press "TIME/off", the display shows the pervious
step turn-on time by default. Press "TIME/off"
continuously to set the turn-off time. Such as
set the shutdown time at 13:00pm (the display
as figure), see below: E
A
B
C
D
E
7) Press "+/−" to setting the target temperature
(Temperature range 10-49°C),
8) Repeat steps 2-7 above, you can set the whole
weekly program, press "OK" to confirm the
setting.
9) To cancel the weekly function, press the "P"
again, the light "P" will go off. The weekly
program is off. The product will revert to the
previous function working status.
Note:
-
After the above setting are completed and P
program is working, press "DAY / EDIT / TIME/
on / TIME/off" to check the setting time of each
day and time periods,
-
The turn-on time periods 00~24hours, cannot
set to minutes ;
-
The "TIME/OFF" can not be less than "TIME/ON";
-
When the"TIME/ON" is the same as "TIME/OFF",
the time period enter into standby mode;
SET OPEN-WINDOW DETECTION
(ONLY by remote control):
1. Press "
", the product enter into working
status. Heating for a moment untill stable.
2. Press "
" by remote control, light
"
/°C" will on; The temperature display
"23" by default. Press "+/−" to set target
temperature. During open-window detection
mode, once the ambient temperature drops
5-10°C within 10 minutes, then the product will
stop working within 30 minutes and enter into
stand by mode. Then press "
" to turn on the
product.
3. Press "
" again to turn off the open-window
detection, the light "
" will go off and the
product will resume to previous working mode.
Below F is an example to set 23°C during open-
window detection.
4. When turn on at the same time for both open-
window detection and weekly program, during
the OFF period of weekly program, the product
doesn't work. During the working status of
weekly program, the temperature is subject
to the setting temperature of open-window
detection. Below G is a example:
F
G
Note:
-
Before turn on weekly program: it must set day
and time period, otherwise the weekly default
state is "00", which does not work.
MAINTENANCE AND CLEANING
-
Warning: Never use detergent, chemical
damage plastic parts.
-
WARNING: Let the appliance cool down
completely before handling or cleaning.
-
To prevent risk of fire or electrocution inside the
appliance.
-
Clean the outside wall of the appliance by
rubbing it gently with soft, damp cloth, either
with or without soap.
-
Regularly clean the air inlet and outlet vents of
the fan.
4
TECHNICAL CHARACTERISTICS
220-240V • 50Hz • 2000W
Environment friendly disposal
You can help protect the environment!
Please remember to respect the local
regulations: hand in the non-working electrical
equipments to an appropriate waste disposal
center.
Model
FA-5571-3
Item
Symbol
Value
unit
Item
Heat output
Type of heat input, for electric storage local space heaters
only (select one)
Nominal heat
P
2,0
kW
manual heat charge control, with integrated thermostat
nom
output
Minimum heat
P
0,0
kW
manual heat charge control with room and/or outdoor
min
output (indicative)
temperature feedback
Maximum
P
2,0
kW
electronic heat charge control with room and/or outdoor
max
continuous heat
temperature feedback
output
Auxiliary electricity consumption
fan assisted heat output
At nominal heat
el
0,0
kW
Type of heat output/room temperature control
max
output
(select one)
At minimum heat
el
0,0
kW
single stage heat output and no room temperature control [no]
min
output
In standby mode
el
0,000
kW
Two or more manual stages, no room temperature control [no]
SB
with mechanic thermostat room temperature control
with electronic room temperature control
electronic room temperature control plus day timer
electronic room temperature control plus week timer
Other control options (multiple selections possible)
room temperature control, with presence detection
room temperature control, with open window detection
with distance control option
with adaptive start control
with working time limitation
with black bulb sensor
TIMETRON Raimundgasse 1/8, A-1020 Vienna, Austria
Contact details
unit
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[yes]
[no]
[yes]
[no]
[no]
[yes]
[no]
5