DMG200 - DMG210
D
vailable in German at www.LovatoElectric.com/I269D.pdf
PL
vailable in Polish at www.LovatoElectric.com/I269PL.pdf
W RNING!
– Carefully read the manual before the installation or use.
– This equipment is to be installed by qualified personnel, complying to current standards, to avoid damages or safety hazards.
– Before any maintenance operation on the device, remove all the voltages from measuring and supply inputs and short-circuit the CT input terminals.
– The manufacturer cannot be held responsible for electrical safety in case of improper use of the equipment.
– Products illustrated herein are subject to alteration and changes without prior notice. Technical data and descriptions in the documentation are accurate, to
the best of our knowledge, but no liabilities for errors, omissions or contingencies arising there from are accepted.
circuit breaker must be included in the electrical installation of the building. It must be installed close by the equipment and within easy reach of the operator.
It must be marked as the disconnecting device of the equipment: IEC /EN 61010-1 § 6.11.2.
– Fit the instrument in an enclosure or cabinet with minimum IP40 degree protection.
– Clean the instrument with a soft dry cloth; do not use abrasives, liquid detergents or solvents.
INDEX
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Keyboard functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display of readings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of display pages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Main menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Password access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parameter setting (setup). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parameter table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Energy meters page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hour counters page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trend graph page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commands menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PC-DMG210 connection through RS485 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Terminal arrangement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mechanical dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION
The DMG200 and DMG210 multimeters have been designed to join the maximum possible ease of operation together with a wide choice of advanced functions.
Regardless of the compactness of the modular housing (only 4U), the multimeter performance is the same as high-end devices.
The graphic LCD offers user-friendly interface. The rich variety of functions makes the DMG series multimeters the ideal choice for a wide range of applications.
DESCRIPTION
– Modular DIN-rail housing, 4U (72mm wide).
– Graphic LCD display, 128x80 pixels, white backlighting, 4 grey levels.
– Membrane keyboard with 4 keys for viewing and setting.
– Easy and fast navigation.
– Texts for measurements, setup and messages in 5 languages.
– Reading of 160 electrical parameters.
– DMG210 version with built-in RS485 interface.
– True RMS measurements.
– Continuous (gapless) sampling.
– High accuracy.
KEYBO RD FUNCTIONS
s and t keys - Used to scroll display pages, to select among possible choices, and to modify settings (increment-decrement).
key - Used to move through sub-pages, to confirm a choice, to switch between viewing modes.
MENU key - Used to enter or exit from viewing and setting menus.
DIGIT L MULTIMETER
CZ
vailable in Czech at www.LovatoElectric.com/I269CZ.pdf
RU
vailable in Russian at www.LovatoElectric.com/I269RU.pdf
G
B
Page
1
1
1
2
2
3
3
3
4
5
6
6
6
6
7
8
9
9
9
1
Tabla de contenido
loading

Resumen de contenidos para LOVATO ELECTRIC DMG200

  • Página 28: Introducción

    INTRODUCCIÓN Los multímetros DMG200 y DMG210 han sido diseñados para combinar la máxima simplicidad de uso con una amplia selección de funciones avanzadas. No obstante la forma compacta de la caja modular (sólo 4U), las prestaciones del multímetro son las mismas que las de un aparato de alta gama. La pantalla gráfica LCD hace que la interfaz usuario sea intuitiva.
  • Página 29 VISU LIZ CIÓN DE L S MEDID S – Las teclas s y t permiten pasar las páginas de visualización una por una. La página actual se reconoce por la barra del título. – En base a la programación y conexión del aparato, es posible que algunos parámetros no se visualicen (por ejemplo si está programado para un sistema sin neutro, no se visualizarán los parámetros relacionados a este último).
  • Página 30: Juste De P Rámetros (Setup)

    MENÚ PRINCIP L – El menú principal consta de un conjunto de iconos gráficos que agilizan el acceso a las medidas y configuraciones. – Desde la visualización normal de los parámetros pulsar la tecla MENÚ. La pantalla visualiza el menú rápido. –...
  • Página 31 P01.01 - Corriente nominal del circuito primario de los TC P01.02 - Corriente nominal del circuito secundario de los TC. Para DMG200 y DMG210 es fija, de 5 . P01.03 - Tensión nominal de la instalación. Dejándolo en ut, el multímetro adapta automáticamente la escala de las barras gráficas.
  • Página 32: Págin Cont Dores De Energí

    M04 - INTEGR CIÓN Default Range P04.01 Modo integración Var. Fijo / Variable P04.02 Tiempo integración potencias 1-60 P04.03 Tiempo integración corrientes 1-60 P04.01 - Selección del modo de cálculo de las medidas integradas. Fijo = Las mediciones instantáneas son integradas durante el tiempo programado. Cada vez que termina el tiempo, la medición integrada se actualiza con el resultado de la última integración.
  • Página 33: Descripción

    PÁGIN CUENT HOR S – En la página cuentahoras se visualizan: • cuentahoras total (cuenta el tiempo de alimentación del aparato) • cuentahoras parcial . – Para poner a cero los contadores es necesario acceder al menú de mandos. – La página cuentahoras puede inhabilitarse por completo si la habilitación general cuentahoras está configurada en OFF (véase menú Cuentahoras). PÁGIN GRÁFICO TREND –...
  • Página 34 Poliamida R L 7035 Doble aislamiento hacia alimentación y entradas Grado de protección IP40 frontal voltimétricas IP20 conexiones Precisión Peso 294g (DMG200); 300g (DMG210) Condiciones de medida temperatura 23°C ±2°C Homologaciones y conformidad tensión L-N 50...480V Homologaciones obtenidas cULus, GOST L-L 80...830V UL Marking Supply voltage 100...240V C or 110...250VDC...
  • Página 35: Esquem S De Conexión

    ESQUEM S DE CONEXIÓN Conexión trifásica con o sin neutro Conexión bifásica P01.07 = L1-L2-L3-N L1-L2-L3 P01.07 = L1-N-L2 100...240VAC 100...240VAC 110...250VDC 110...250VDC -- - V2 V3 S1 S2 S1 S2 S1 S2 AUX SUPPLY VOLTAGE CURRENT AUX SUPPLY VOLTAGE CURRENT Conexión monofásica Conexión trifásica equilibrada con o sin neutro...
  • Página 36: Disposición Termin Les Y Dimensiones Mecánic S

    CONEXIÓN PC-DMG210 MEDI NTE PUERTO RS485 Max 1200m Cable 51C4 TR A RS485 Interface converter RS485 RS232/485 DMG210 n°31 DMG210 n°1 Max 1200m Max 1200m Cable 51C4 Repeat this wiring diagram up to 255 devices TR A TR A TR A TR A B SG RS485...

Este manual también es adecuado para:

Dmg210

Tabla de contenido