notICe to InStaLLeR: Instructions must remain with installation.
Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
U P
C
C
®
WATER POWERED EMERGENCY BACKUP
1. Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact
your dealer before using.
2. Read all the installation instructions regarding installing and start up before performing any of the work described within.
Retain for future reference.
SEE BELOW FOR LIST OF WARNINGS
1. For your protection always disconnect the power supply
from its power source before handling the components of
your primary pump.
2. Sump water is non-potable. To reduce the risk of contamination
of the potable water supply, the Home Guard
be installed with a listed backflow device suitable for the
installation, in accordance with the local plumbing code,
such as a reduced pressure principle backflow preventer
(RP). Alternately, consult the local plumbing and health
codes or the authority having jurisdiction for guidance on
cross-connection and backflow protection requirements.
Turbulence caused by high velocity incoming
CAUTION
water can negatively affect the on/off action of the float
mechanism. If this condition exists, the incoming water must
be baffled to avoid excessive turbulence.
S
TAR
HomeGuard
OPTIMA
MODEL S1503
SUMP PUMP SYSTEM
PVC CONSTRUCTION
PREINSTALLATION CHECKLIST
Optima must
®
RefeR to WaRRanty on page 2.
© Copyright 2015 Star Water Systems All rights reserved.
®
®
CAUTION
SEE BELOW FOR LIST OF CAUTIONS
1. This pump is designed for handling clear water. Do not use in
septic tanks to pump effluent or sewage pits to pump sewage.
2. Repair and service of your backup system should be performed
by an authorized service station.
3. The installation of this backup pump requires the use of a
variable level float switch for operation. It is the responsibility
of the installing party, to ensure that the float switch will not
hang up on the pump apparatus or pit peculiarities and is
secured so the pump will turn "on" and "off". It is recommended
that the pit be 18" in diameter or larger to accommodate both
a primary and a backup pump.
4. Check the installation of the primary and backup pump floats
to ensure that both move freely and are not being encroached
upon where the float cannot move. Adequate space between
the floats must be maintained.
5. The pump should be manually activated once a month by
lifting the float rod. Let the pump run for at least 15 seconds
to prevent the pump from building up calcium deposits and
debris, which could harm the pump.
FW1379 0615
Supersedes 0913
visit our web site:
starwatersystems.com
Register your Star Water Systems
product on our website at:
http://reg.starwatersystems.com/

Publicidad

Tabla de contenido
loading

Resumen de contenidos para STAR Water Systems S1503

  • Página 9: Sistema De Bomba De Sumidero Auxiliar De Emergencia Accionada Por Agua

    Mantenga la bomba encendida durante por lo menos 15 segundos para prevenir la acumulación de depósitos de calcio y escombros que podrían dañarla. RefIÉRaSe a La gaRantÍa en La pÁgIna 2. © 2015 Star Water Systems. Todos los derechos reservados.
  • Página 10: Garantía Limitada

    7. EXAMINE todos los códigos nacionales y locales pertinentes y verifique dentro de 1.8 m (6 pies) del Home Guard ® Optima. que la instalación se realice conforme a cada uno de ellos. © 2015 Star Water Systems. Todos los derechos reservados.
  • Página 11: Instalación

    (RP). Consulte los códigos locales de plomería y salud o las autoridades que tienen jurisdicción para los requisitos de protección de reflujo. © 2015 Star Water Systems. Todos los derechos reservados.
  • Página 12: Paso 5: Verificación Del Funcionamiento De La Bomba

    3,8 litros (1 galón) para extraer 1.5 galones de agua del foso. A medida que aumente la presión del suministro de agua, con una carga estática constante, disminuirá la cantidad de agua requerida. © 2015 Star Water Systems. Todos los derechos reservados.
  • Página 13 © 2015 Star Water Systems. Todos los derechos reservados.
  • Página 14: Características De Rendimiento

    La válvula de aspiración está encima Ajuste el flotador - Refiérase al PASO 2. del nivel de agua. La descarga vertical es demasiado Cambie la tubería de descarga o solicite asistencia técnica. alta. © 2015 Star Water Systems. Todos los derechos reservados.
  • Página 15: Desglose De Los Componentes En La Ilustración

    * Ítems incluidos en el juego de reposición. ** La válvula de pie se debe cortar lo más cerca posible de la parte superior y la válvula nueva se debe fijar con pegamento. SK2741 © 2015 Star Water Systems. Todos los derechos reservados.
  • Página 16 © 2015 Star Water Systems. Todos los derechos reservados.

Este manual también es adecuado para:

Homeguard optima

Tabla de contenido