9. LED INDICATORS

In Silenplus pump:
The possible LED combinations and their meanings are:
0 = LED OFF
1 = LED ON
2 = LED flashing slowly
3 = LED flashing quickly
AUTO/
BACKWASH
MANUAL/
Plus
FAULT
0
0
0
1
0
1
1
0
1
1
1
1
2
0
3
3
(.. .t og e th er ...)
3
0
3
1
3
1
2
1
2
1
When moving the control of the ControlSystem:
Number of flashes
3
2
1
0
FILTRATION
Equipment status
Plus
Functions
1
Filtration Plus function in Auto mode.
0
Backwash Plus function in Auto mode.
1
Mixed Cycle function in Auto mode. Motor at 100%.
1
Filtration Plus function in Manual mode.
0
Backwash Plus function in Manual mode.
1
Mixed Cycle function in Manual mode.
"Standby" mode. The equipment has power, motor stopped.
a) Valve in intermediate positions or position 6 in Auto mode.
0
b) Stop function in Manual mode.
c) Timer OFF position.
Configuration
3
Initial configuration: standing by for link with ControlSystem
1
Filtration Plus speed setting.
0
Backwash Plus speed setting.
1
Mixed Cycle speed setting.
2
No water error. Start-up retry attempted.
1
No water error. Full shut-down.
ControlSystem status
The ControlSystem is not linked to any Silenplus.
Communication error. Call for service.
The ControlSystem works correctly.
Replace the ControlSystem battery