OVERVIEW
MAIN UNIT
1
2
3
8
9
10
11
12 13
14
15 16 17
1.
[ TIME SET ] key
- In normal mode, press and hold for 2 seconds to enter time setting mode.
- In time setting mode, press to step next setting of time and calendar.
2.
[ ALARM ] key
- In normal mode, press to show the alarm time and turn on/off the alarm.
- In normal mode, press and hold for 2 seconds to enter alarm setting mode.
- In alarm setting mode, press to step next setting of alarm.
- When alarm is sounding, press to stop the current alarm.
- In alert setting mode, press to toggle the HI / LO alert on/off.
3.
[ ALERT ] key
- In normal mode, press and hold for 2 seconds to enter temperature alert setting
mode.
- In alert setting mode, press once to switch between setting options.
-
to normal mode.
4.
[ ALARM / SNOOZE ] key
- When alarm is sounding, press to stop the current alarm and enter snooze.
- When alarm is sounding, press and hold for 2 seconds to stop the current alarm, the
clock will sound again in the next day.
4
5
6
7
18
5.
[ CHANNEL / + ] key
- In normal mode, press to switch between Channel 1~8 of outdoor sensors.
- In normal mode, press and hold for 2 seconds to enter auto-cycle mode of Channel
1~8 temperature readings.
- During auto-cycle mode, press once to return to normal mode.
- In setting mode, press to increase the setting values.
6.
[ MEM / - ] key
- In normal mode, press to check maximum and minimum temperature reading.
- During max or min record is displayed, press and hold for 2 seconds to erase the
current records.
- In setting mode, press to decrease the setting values.
7.
[ INDEX ] key
- In normal mode, press to toggle the between dew point and heat index
8.
LCD display
9.
Battery compartment
- Accommodates 3 x AAA batteries for backup.
10. Power jack
11. Wall mount hole
12. [ HISTORY ] key
- In normal mode, press to view the past 24 hour weather records.
13. [ HI / LO / AUTO ] sliding switch
- Slide to the [ HI ] position for brighter backlight.
- Slide to the [ LO ] position for dim backlight.
- Slide to the [ AUTO ] position for Auto backlight that depends on the environment
brightness.
14. [ SENSOR ] key
- Press once to enter sensor receiving mode.
15. [ BARO ] key
- In normal mode, press to switch baro pressure unit
- In normal mode, press and hold for 2 seconds to enter rel/abs mode
16. [ RESET ] key
- Press once to perform overall function reset.
- In case of malfunction, the unit may require reset.
17. [ °C / °F ] key
- In normal mode, press to switch between °C /°F format.
18. Extend wall mount holder
- To mount the main unit in horizontal viewing angle
LCD DISPLAY
1
2
3
4
1.
Weather forecast and baro reading section
2.
Outdoor humidity section
3.
Outdoor temperature section
4.
Time, calendar and weather index display section
5.
Indoor humidity section
6.
Indoor temperature section
WIRELESS HYGRO-THERMO SENSOR WITH RCC RECEIVE FUNCTION
1
1.
Transmission status LED
4.
2.
[ RCC ] receive key
5.
- Press for RCC receiving.
- Assign the sensor to Channel 1,2,3,4,5,6,7 or 8.
3.
[ RESET ] key
6.
- Accommodates 2 x AA size batteries.
4
5
2
3
6
Wall mounting holder
[ CHANNEL ] slide switch
Battery compartment
5
6

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Emos ESW5002

  • Página 21: Pantalla Lcd

    CON PANTALLA A COLOR Botón [ CHANNEL / + ] Modelo: ESW5002 Manual de Usuario - En modo normal, pulse para cambiar entre el canal 1~8 de los sensores exteriores. - En modo normal, mantenga pulsado durante 2 segundos para entrar en el modo de ciclo automático de lecturas de temperatura del canal 1~8.
  • Página 22: Unidad Principal

    CÓMO EMPEZAR RECEPCIÓN DE LA SEÑAL DE RADIOCONTROL SENSOR INALÁMBRICO La hora y fecha están controladas por radio. La hora y fecha actuales se sincronizan automáticamente con la señal que se transmite desde la estación RC a través del Retire la tapa de las pilas. sensor inalámbrico.
  • Página 23: Funciones De Temperatura

    AJUSTE Y VISULIZACIÓN DE LA HORA DE ALARMA En el modo de hora normal, mantenga pulsada la tecla [ ALARM ] durante 2 segundos hasta que la hora de la alarma parpadee en el modo de ajuste de alarma. Pulse el botón [ CHANNEL / + ] o [ MEM / - ] para cambiar el valor. Mantenga o el botón para para un ajuste rápido.
  • Página 24: Registro De Max/Min

    1% para la humedad. También puede mantener pulsado el botón para ajustar rápidamente el valor. Por la presente, Emos spol. s r. o. declara que el tipo de equipo radioeléctrico Al ajustar el valor de la temperatura alta o baja, pulse el botón [ ALARM ] para ESW5002 es conforme con la Directiva 2014/53/UE.

Tabla de contenido