The TM-2000 Humidifier is activated by heated air being produced by your furnace. Its thermal sensing circuitry
monitors the temperature of the heated air. When the air is warm enough, the Housing Assembly's electric
water valve is actuated, opening to allow cold water from your plumbing system to be atomized into a fine mist.
This mist is discharged into the heated air by the Remote Nozzle Bracket Assembly, where it immediately
evaporates and is distributed throughout your household. The TM-2000 is supplied water from your plumbing
system by the Saddle Valve Assembly, and is safely powered with reduced voltage by the 120/24 VAC
Transformer, which plugs into an ordinary 120-volt wall outlet.
The TM-2000 is ideal for use with conventional gas or oil forced-air central heating systems.
WARNING: The TM-2000 is not be used on 90+ condensing furnaces, electric heat pumps or homes
with well-water systems.
I
: (DO NOT INSTALL HUMIDIFIER IF ALL OF THESE ITEMS ARE NOT PRESENT!)
TEMS INCLUDED IN KIT
Housing Assembly
Plastic Tubing (3 - 10' Sections)
Housing Mounting Template
Remote Mounting Template
Power Supply Wire
Quick Connect Terminals (2)
120/24 VAC Transformer
Instruction Manual
O
PTIONAL ACCESSORIES
Air Booster Activator Kit
Humidistat
NOTE:
The TM-2000 is designed to operate on normal city water supply
pressure. If any other type of water supply is to be used it must be capable of
providing a minimum pressure of 50 psi.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE OF REPLACEMENT PARTS, OPTIONAL
WHOLE HOUSE HUMIDIFIER
Model: TM-2000
Housing Assembly
Remote
Nozzle Bracket
:
DO NOT DESTROY
COMPONENTS, AND TROUBLESHOOTING INFORMATION.
Saddle Valve Assembly
Remote Nozzle Bracket
Saddle Valve Assembly
Includes 5 Each: Compression Nuts, sleeves, and inserts
Mounting Components
Includes: (4) #8-15 X 3/4" Hex Head Housing
(3) #8-15 X 1/2" Hex Head Remote
Bracket Mounting Screws
(3) #8 Speed Nuts For Remote Bracket Mounting.
Plastic Tubing (3-10' Sections)
10' Power Supply Wire
120VAC/24VAC
Transformer
English ...... Page 1
Français..... Page 8
Espanõl ..... Page 14
PRODUCT QUESTIONS...
CALL FIELD FIRST
for answers on product maintenance,
operation or replacement part questions.
Phone:
(252)522-3031
E-mail:
fieldtec@fieldcontrols.com
Tabla de contenido
loading

Resumen de contenidos para Field Controls TM-2000

  • Página 14: Humidificador Para Toda La Casa

    La Figura 6) En ciertas instalaciones, tal vez sea necesario extender más la boquilla con un juego de opcional extensión EK-1 de Field Controls. (Vea La Figura 7) Un 45° para redirigir el rocío sin extender la boquilla. Si existe un aire acondicionado “A-COIL”...
  • Página 15 Figura 3 Figura 4 Figura 5 Figura 6 Figura 8 Figura 7 Page 15...
  • Página 16 23. Asegúrese que el interruptor de potencia del conjunto de la cubierta esté en la posición “OFF” (APAGADO) y conecte el transformador al tomacorriente. El transformador debe suministrar ahora 24 voltios CA al TM-2000. JUSTE DEL UMIDIFICADOR El TM-2000 debe estar ajustado ahora de tal manera que se active después que comience la circulación de aire caliente, Page 16...
  • Página 17: Mantenimiento

    3. Aproximadamente 2 minutos después de que la caldera comience a soplar aire caliente a través de los conductos, gire la perilla de ajuste en sentido contrario de las agujas del reloj hasta que se active el TM-2000. Esto se indicará al iluminarse la luz “ON”...
  • Página 18: Guía Para Solución De Problemas

    “ON” (ENCENDIDO) para obtener mayor temperatura, o trate de localizar una posición que sea adecuada para el requerimiento de temperatura. 3. El TM-2000 se enciende después que el ventilador de la caldera se apaga o el TM-2000 se mantiene encendido después de apagarse el ventilador.
  • Página 19 5. El suministro de agua más cercano está a más de 10 pies de la ubicación del TM-2000. a. Si el suministro de agua más cercano está a más de 10 pies de la ubicación del TM-2000, se recomienda que la conexión de agua se haga solamente con tubería de cobre del mismo tamaño (1/4 de pulgada de diámetro...
  • Página 20: Warranty Information

    GARANTÍA LIMITADA DE UN AÑO Se garantiza que los productos de The Field Controls Co. están libres de defectos en material y mano de obra bajo uso normal durante un año a partir de la fecha de compra. En caso de un mal funcionamiento o falla de este producto, el comprador deberá empaquetar toda la unidad debidamente y enviarla con PORTE PAGADO con la dirección de regreso, a la dirección indicada a continuación.

Tabla de contenido