Passive Infrared Vacancy Sensors RMS100, RMS120 and
Passive Infrared Occupancy Sensors RMS101, RMS121
Vacancy and Occupancy sensors use passive infrared detection and a microcontroller to maximize energy savings and
minimize turning off lights in an occupied room.
Hubbell offers 4 models:
Vacancy Sensor: RMS100, RMS120 120VAC, 60 Hz (Ivory, White, Almond, Light Almond)
Occupancy Sensor: RMS101, RMS121 120VAC, 60 Hz (Ivory, White, Almond, Light Almond)
Lighting Load: 120VAC: 25Watts minimum, 500Watts maximum incandescent only (Do not use with
fluorescent lamps).
Time Delay: Manual adjustment behind front press switch: 30 second minimum, 30 minutes maximum.
Daylight Control (Occupancy Sensor Only): Press one button to set ambient light level (Photocell).
Manual Override Front Press Switch (FPS): Switches lights "on" or "off", (See Front Press switch Basic
Operation Below). Note: FPS must be pressed to turn light on.
Motion Indicator: Highly visible green LED.
Reset to Factory Setting: Hold front press switch for 10 seconds resets the sensor to the factory settings.
50% dim down: Lights dim to 50% 30 seconds before they switch off.
Coverage Area approximately 800ft² (74m²) See coverage area below.
Passive infrared (IR) sensors are activated by changes in IR temperature in the coverage area.
The product must be installed in the line-of-sight of the occupant. The sensor should not be installed:
16'
16'
NOTICE: Designed for hard wire circuits only, do not use to control receptacles. For installation by a qualified electrician
in accordance with national and local electrical codes and the following instructions.
CAUTION: RISK OF ELECTRIC SHOCK. Disconnect power before installing.Never wire energized electrical
components. Mandate required OSHA lockout, tag out procedures.
CAUTION: USE COPPER CONDUCTORS ONLY.
CAUTION: Use only in indoor, dry locations. Sensor's maximum operating ambient temperature = 50ºC.
CAUTION: To Reduce the Risk of Overheating And Possible Damage To Other Equipment, Do Not Install
To Control A Receptacle, A Motor-Operated Appliance, A Florescent Lighting Fixture, Or A Transformer-
Supplied Appliance.
Single-Gang Installation ONLY
INSTALLATION INSTRUCTIONS
35'
Horizontal Coverage
Mounting
Height
36" to 54"
(91.44 to 137.16 cm)
35'
Vertical Coverage
PD2203
loading

Resumen de contenidos para Hubbell homeSELECT RMS100

  • Página 5 Los sensores de ausencia y de presencia utilizan detección infrarroja pasiva y un microcontrolador para maximizar los ahorros de energía y minimizar el apagado de las luces en una habitación ocupada. Hubbell ofrece 4 modelos: Sensores de ausencia: RMS100, RMS120 120 V~, 60 Hz (marfil, blanco, almendra, almendra claro) Sensores de presencia: RMS101, RMS121 120 V~, 60 Hz (marfil, blanco, almendra, almendra claro) Carga de alumbrado: 120 V~: 25 W mínimo, 500 W máximo sólo incandescente (no debe usarse con lámparas fluorescentes).
  • Página 6 S.A. DE C.V. HUBBELL reparará o reemplazará a su juicio el producto en un plazo de 60 días. Esta Av. Coyoacán N° 1051 garantía no cubre desgastes por uso normal o daños ocasionados por accidente, mal...

Este manual también es adecuado para:

Homeselect rms120Homeselect rms101Homeselect rms121