7.
System settings
7.1.
Service menus
)* With SANARIUM controller 18033/18040 with function.
)* With Sauna controller 18029/18040 without function (changes to these values are not applied).
No.
Menu
34
SM_I
Setting the sauna heater type
35
SM_P
Calibrating the heat-up phase
Input
Setting the sauna heater type for monitoring the heat-up phase for remote start or
preset time mode.
0
Increase of 5 Kelvin within 3 minutes (default),
Majus/Sanarium M sauna heaters 6-12 kW,
Pluris/Pluris Softlcima 4.5-9 kW,
Trumpf 3-9 kW,
Softclima 3-7.5 kW
1
Increase of 5 Kelvin within 2 minutes,
Majus sauna heaters 16-30 kW,
Pluris Softclima 12 kW,
Softclima 9 kW
2
Increase of 5 Kelvin within 5 minutes,
Pluris Softclima sauna heater 3 kW
3
Not used
4
Not used
5
Individual heat-up curve. Calibration via service menu point 35.
Calibrating the heat-up phase for switching on via remote start, preset time mode or
the app.
.
Only carry out this process when the cabin and the sauna heater are cold.
Otherwise, the measured values will be distorted and the monitoring will not
work correctly during operation.
'
Carry out the calibration process, see page 29.
Continued
Display
(example)
Continued on the next page