Installation And Operation; Air Line Components; Bench Test; Priming - Alemite 331571-A5 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation and operation


WARNING
Do not exceed lowest pressure rating of
any component in system.
Failure to comply may result in
serious injury or death.
WARNING

Do not operate pump with broken,
missing or defective parts. Replace
defective parts prior to operation.
Failure to comply may result in
serious injury or death.
WARNING

Do not operate with leakage in system.
Disconnect air to motor.
Failure to comply may results in
serious injury.

Air line components

Item
Description
338860
Moisture separator/regulator and gauge combination
5604-3
Moisture separator
7604-B
Regulator and gauge
5904-3
Lubricator
1)
Although air motor is lubricated at factory, the life of motor can be extended with use of a lubricator.

Bench test

NOTE
Perform the following procedures at a
pressure not to exceed 25 psi (1.7 bar).
With air pressure at zero:
1 Connect air to inlet of air motor.
2 Slowly supply air pressure to pump motor.
3 Pump should cycle. If pump does not cycle,
refer to Troubleshooting, page 14 for
details.

Priming

With air pressure at zero:
4 Connect product hose to material outlet.
5 Direct hose into an appropriate collection
container.
6 Place pump in product.
7 Slowly supply air pressure to pump motor.
8 Allow pump to cycle slowly until system and
product is free of air.
9 If pump does not prime, refer to
Troubleshooting, page 14 for details.
1)

Stall test

With air pressure at zero:
10 Attach a control valve to outlet hose of
11 Set air pressure to 35 psi (2.4 bar).
12 Operate control valve into a container.
13 Allow pump to cycle until system and prod-
14 Shut off control valve.
15 Set air pressure to 100 psi (7 bar).
16 Visually inspect pump for external leaks.
17 Pump should not cycle. If pump does not

Leakage

18 Check motor for air leakage.
19 If motor leaks, refer to 670628 for details.

Installation

Additional items that should be incorporated
into air piping system are illustrated in
Air line components (→ Table 5).
Table 5
13
pump.
uct is once again free of air.
stall, refer to Troubleshooting, page 14
for details.
Tabla de contenido
loading

Este manual también es adecuado para:

331571-b5331571-c5

Tabla de contenido