Other Technical Data; Gas Burners For Natural Gas G20 20 Mbar; Gas Burners For Lpg G30/G31 28-30/37 Mbar; Energy Efficiency - Electrolux Rgg6741 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

9.3 Other technical data

TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:

9.4 Gas burners for NATURAL GAS G20 20 mbar

BURNER
Rapid
Semi-rapid
Auxiliary

9.5 Gas burners for LPG G30/G31 28-30/37 mbar

BURNER
Rapid
Semi-rapid
Auxiliary

10. ENERGY EFFICIENCY

10.1 Product information according to EU 66/2014

Model identification
Type of hob
Number of gas burners
Energy efficiency per gas burner
(EE gas burner)
Gas original:
Gas replacement:
230 V ~ 50 Hz
II2H3+
G 1/2"
3
NORMAL POWER
kW
3,0
2,0
1,0
NORMAL
MINIMUM
POWER
POWER
kW
kW
2,8
0,75
2,0
0,45
1,0
0,33
G20 (2H) 20 mbar = 8 kW
G30 (3+) 28-30 mbar = 567 g/h
G31 (3+) 37 mbar = 557 g/h
MINIMUM POWER
kW
0,75
0,45
0,33
INJECTOR
MARK 1/100
mm
86
71
50
Left rear - Semi-rapid
Right rear - Semi-rapid
Left front - Rapid
Right front - Auxiliary
ENGLISH
INJECTOR MARK
1/100 mm
119
96
70
NOMINAL GAS FLOW g/h
G30 28-30
G31 37 mbar
mbar
204
200
145
143
73
71
RGG6741NOX
Built-in hob
4
54.2%
54.2%
59.3%
not applicable
15
Tabla de contenido
loading

Tabla de contenido