Cleaning and Maintenance
Disconnect the device from the mains prior to maintenance activities.
The power supply cables must not show any damage. Have a qualified technician maintain the device.
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
There are no user-serviceable parts, apart from the fuse. Contact your dealer for spare parts if necessary.
Store the device in a dry, well-ventilated, dust-free room.
7.
Technical Specifications
input voltage .............................................................. 110 VAC, 60 Hz, 1 A, 126 W, pf: 0.55
output voltage ............................................................................ 0-30 VDC adjustable max.
output current .................................................................................. 0-3 A adjustable max.
ripple voltage .................................................................................................. 200 mVp-p
dimensions .............................................................................. 3
weight ................................................................................................................ 2.94 lbs.
fuse ....................................................................................................................... T3.15
Use this device with original accessories only. Velleman Inc. cannot be held responsible in the event
of damage or injury resulting from (incorrect) use of this device. For more info concerning this
product and the latest version of this manual, please visit our website www.vellemanusa.com. The
information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman Inc. All worldwide rights reserved. No part of this
manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the
prior written consent of the copyright holder.
V. 01 – 13/09/2018
LABPS3003SMU
5
11/32
× 6
19/64
× 8
5/64
inch
©Velleman Inc.

Publicidad

loading