Single-User Vs. Multi-User Diagnostic Mode; Audio Reference - Bruno Sre-3000 Elan Manual De Instalación

Ocultar thumbs Ver también para SRE-3000 ELAN:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ELECTRICAL
SINGLE-USER VS . MULTI-USER DIAGNOSTIC MODE
NOTICE:
Before touching anything inside carriage
assembly, ground yourself by touching an unpaint-
ed metal surface on unit such as an exposed bolt,
or one of the mounting screws on electrical panel.
While working, periodically touch an unpainted
metal surface to dissipate any static electricity that
could harm internal components.
loosen
only
left–middle–right
©Bruno Independent Living Aids, Inc.
NOTES: Units ship in multi-user mode .
Changing Multi-User to Single-User Mode
1. Turn circuit breaker on carriage to OFF.
2. Loosen, but do not remove top carriage
cover screws.
3. Remove top carriage cover (Fig. 1).
Fig. 1
4. Change diagnostic mode by pulling jumper
off (Fig. 2) and pushing it on to two (2)
right-hand pins.
DIAGNOSTIC MODE
Multi-User
Single-User
jumper
Fig. 2
38
®
Multi-user mode means that when
seat is swiveled at top of rail, unit
beeps once every three (3) seconds .
Single-user mode means that when
seat is swiveled at top of rail,
no beeps are heard .

AUDIO REFERENCE

Chirp
0.25 second
Short Beep
0.50 second
Long Beep
1.50 seconds
Pause
1.00 second
pins under jumper
left and middle
middle and right
SRE-3000 INSTALLATION 02-08-2019
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

3000-i

Tabla de contenido