Idiomas disponibles

Idiomas disponibles

H-9460
EYEWASH DRENCH HOSE –
WALL MOUNT
TOOLS NEEDED
Electric
1/4" Drill Bit
Drill
8' Hose x 1
CAUTION! In the event of a chemical splash or
spill, affected area of the victim's body must
be flushed immediately for at least 15 minutes.
For chemical spills to the eyes, user should
hold eyes open as wide as possible to permit
water to reach all areas around the eye.
NOTE: Unit should be installed by licensed
plumber.
NOTE: Thoroughly clean and flush supply line
prior to installing unit. Pipe shavings, scale,
tape and other debris can be carried through
a pipe and into unit when system is activated.
This debris can damage valve components
and interfere with proper operation of the valve.
• The water supply line should have outside diameter
of at least 1/2" and should be copper or other
corrosion-resistant material.
PAGE 1 OF 6
Phillips
Screwdriver
Handle x 1
Wall Bracket x 1
1-800-295-5510
uline.com
PARTS
Screw x 4
SAFETY
CAUTION! Rinsing affected area for 15 minutes
is only the first step in treating exposure to a
hazardous chemical. Following rinsing, victim
should be examined and treated by a doctor
or other trained medical specialist as soon as
possible.
INSTALLATION
• Unit has a 3/8" NPT male thread on inlet.
(See Figure 1) Use Teflon® tape or other pipe sealant
to seal thread. Do not apply sealant in a way that
will allow it to enter into unit.
Figure 1
Para Español, vea páginas 3-4.
Pour le français, consulter les pages 5-6.
Spray Head x 2
Inlet
3/8" NPT
Male Thread
0421 IH-9460
Squeeze
Valve x 1
Tabla de contenido
loading

Resumen de contenidos para Uline H-9460

  • Página 3: Lavaojos Con Manguera De Enjuage - Instalación En Pared

    H-9460 800-295-5510 uline.mx LAVAOJOS CON MANGUERA DE ENJUAGE – INSTALACIÓN EN PARED HERRAMIENTAS NECESARIAS Taladro Broca de 1/4" Desarmador Eléctrico de Cruz PARTES 1 Manguera de 8' 1 Mango 1 Soporte de Instalación 4 Tornillos 2 Cabezales Difusores 1 Válvula en Pared de Presión...
  • Página 4: Mantenimiento

    Inspección de Cumplimiento Anual: Todo equipo de emergencia debe inspeccionarse al menos una vez al año para verificar su cumplimiento continuo de las disposiciones de ANSI Z358.1-2014. 800-295-5510 uline.mx PAGE 4 OF 6 0421 IH-9460...

Tabla de contenido