5.1.1 To open the indoor unit ..........Daikin website (publicly accessible). Installing the indoor unit ............▪ The full set of latest technical data is available on the Daikin 5.2.1 To install the mounting plate ........extranet (authentication required). 5.2.2 To drill a wall hole ............
Preparing the installation site (mm) WARNING The appliance shall be stored in a room without continuously operating ignition sources (example: open flames, an operating gas appliance or an operating electric heater). (A)(F)TXP20~71L2V1B + FTXF20~71A2V1B Installation manual Daikin room air conditioner 3P512025-1C – 2018.01...
2 Remove the front panel by sliding it to the left or the right and on the front grille. pulling it toward you. 3 Install the air filter and then mount the front panel. Installation manual (A)(F)TXP20~71L2V1B + FTXF20~71A2V1B Daikin room air conditioner 3P512025-1C – 2018.01...
4 Finish the installation by securing the mounting plate on the wall using screws. INFORMATION The removed pipe port cover can be kept in the mounting plate pocket. (A)(F)TXP20~71L2V1B + FTXF20~71A2V1B Installation manual Daikin room air conditioner 3P512025-1C – 2018.01...
To connect the piping on right-side, right-bottom, left-side or left- bottom, the pipe port cover MUST be removed. 1 Cut off the pipe port cover from inside the front grille using a coping saw. Installation manual (A)(F)TXP20~71L2V1B + FTXF20~71A2V1B Daikin room air conditioner 3P512025-1C – 2018.01...
2 Remove the drain plug on the left side and attach it to the right side. (A)(F)TXP20~71L2V1B + FTXF20~71A2V1B Installation manual Daikin room air conditioner 3P512025-1C – 2018.01...
Make sure to insulate all refrigerant piping. Any exposed Connecting the refrigerant piping piping might cause condensation. DANGER: RISK OF BURNING Connecting the electrical wiring DANGER: RISK OF ELECTROCUTION Installation manual (A)(F)TXP20~71L2V1B + FTXF20~71A2V1B Daikin room air conditioner 3P512025-1C – 2018.01...
Small animals that make contact with electrical parts can cause malfunctions, smoke or fire. Drain hose Caulk this hole with putty or caulking material. (A)(F)TXP20~71L2V1B + FTXF20~71A2V1B Installation manual Daikin room air conditioner 3P512025-1C – 2018.01...
Address jumper NOTICE Model Button FTXP-L and ATXP-L Be careful NOT to damage any of the surrounding parts Keep pressed for about when cutting the address jumper. 5 seconds. Installation manual (A)(F)TXP20~71L2V1B + FTXF20~71A2V1B Daikin room air conditioner 3P512025-1C – 2018.01...
The stop valves (gas and liquid) on the outdoor unit are fully open. To perform a test run Prerequisite: Power supply MUST be in the specified range. Prerequisite: Test run may be performed in cooling or heating mode. (A)(F)TXP20~71L2V1B + FTXF20~71A2V1B Installation manual Daikin room air conditioner 3P512025-1C – 2018.01...
9 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of latest technical data is available on the Daikin extranet (authentication required). Wiring diagram Unified Wiring Diagram Legend For applied parts and numbering, refer to the wiring diagram on the unit.