WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, disable the ventilator by cover-
ing the solar panel with cardboard or disconnecting the wires
from the motor terminals (note wire locations when disconnect-
ing).
3. Installation work must be done by a qualified person(s) in ac-
cordance with all applicable codes and standards, including
fire-rated construction codes and standards.
4. If removing an existing 120 VAC powered attic ventilator, use
only a qualified person(s) to remove any electrical wiring in
accordance with all applicable codes and standards.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer's guidelines and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Condition-
ing Engineers (ASHRAE), and the local code authorities.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
TOOLS AND MATERIALS REQUIRED
r
Slotted Screwdriver
r
Drill
r
1/4" Drill Bit
r
Sabre Saw or Keyhole Saw
r
Hammer
r
Ruler / Tape Measure
r
Pencil, Marker or Scribe
r
Utility Knife
r
Pry Bar (to remove roofing nails)
r
5/16" Socket and Extension
r
Roofing Cement
r
Galvanized Roofing Nails (1¾" min.)
MODELS 345RSOBK • 345RSOWW
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This unit has an unguarded impeller. Do not use in locations readily
accessible to people or animals.
4. This ventilator operates when the solar panel is exposed to sun
light. To reduce risk of injury while installing, servicing or clean-
ing unit, cover the solar panel with cardboard or disconnect the
wires from the motor terminals (note wire locations when discon-
necting).
5. The recommended open air inlet for this ventilator is 2 square
feet. The best location for these air intake vents are under the
eaves with direct access to the attic. Failure to provide these in-
takes could cause natural-draft gas appliances to backdraft.
6. Your attic fan installation will create a screened opening into
your attic space. During a heavy rain storm there could be a light
spray of rain into this attic space. This is a normal condition with
all attic ventilators and will not cause any damage to the struc-
ture. We recommend that you do not store any valuable articles
directly under the fan opening in the roof.
7. This ventilator is intended for roof installation. Broan Models 353,
345GOBK & 345GOWW Gable Mount Ventilators are available
for side wall applications.
8. The plastic ventilator dome and base may be painted with high
quality paint. Follow the paint manufacturer's recommendations
for acrylic and ABS plastic as appropriate. Take care to avoid
getting paint on the solar panel.
9. This ventilator includes a permanently lubricated motor. Do not
oil or disassemble.
10. The installation instructions contained in this document are only
a recommendation and individual professionals may have their
own methods of installation. If your roof has an existing warranty,
installation of this product by anyone other than those who in-
stalled the roof may jeopardize any future warranty claim. Please
check with the original installer of your roof if this is a concern.
11. When working with asphalt shingles in cold weather (below
40
F), take care to avoid damage to the shingle edges and cor-
o
ners.
12. For installations in climates where cold weather condensation
is not a concern, Broan Model CWT45 thermostat is available.
It disconnects power to the motor when the temperature drops
below 50
F. Power is applied to the motor when the temperature
o
reaches 61
F.
o
Register your product online at:
www.broan.com/register
Page 1
Tabla de contenido
loading

Resumen de contenidos para Broan 345RSOBK

  • Página 8 MODELS 345RSOBK • 345RSOWW Page 8 79040169C...
  • Página 16 MODÈLES 345RSOBK • 345RSOWW Page 16 79040169C...
  • Página 17: Ventilador Solar Remoto Para Ático De Montaje En El Techo

    7. Este ventilador está diseñado para instalarse en el techo. Los Engineers, ASHRAE), y las autoridades de los códigos locales. ventiladores para montaje en hastial Broan Modelos 353, 345GOBK 6. Al cortar o perforar a través de la pared o del techo, tenga cuidado y 345GOWW están disponibles para aplicaciones en muros laterales.
  • Página 18: Instalación

    MODELOS 345RSOBK • 345RSOWW Página 18 INSTALACIÓN Nota: Este ventilador tiene capacidad para reemplazar un ventilador para ático existente de 120 voltios. Sólo el personal calificado debe quitar el cableado eléctrico de acuerdo con los códigos y las normas locales.
  • Página 19 MODELOS 345RSOBK • 345RSOWW Página 19 7. Desde el lado del techo, usando el orificio guía como punto central, use un clavo y un cordón para marcar un círculo de 16 1/2 pulg. (42 cm) de diámetro sobre 10. Perfore un orificio iniciador grande para la sierra de las tejas.
  • Página 20 MODELOS 345RSOBK • 345RSOWW Página 20 13. Aplique un cordón grande de cemento para techo en 15. Con un buen cemento con grado para techo selle todas la ranura moldeada en la parte inferior de la base del las tejas y las cabezas de los clavos. NO selle el borde ventilador.
  • Página 21: Instalación Del Panel Solar Remoto

    MODELOS 345RSOBK • 345RSOWW Página 21 INSTALACIÓN DEL PANEL SOLAR REMOTO 17. Desde el interior del ático, encuentre el centro de la ubicación seleccionada para el panel solar identificada en el paso 2, perfore un orificio pequeño en la cubierta del techo, lo suficiente grande como para que pase el cable del panel solar.
  • Página 22: Piezas De Servicio

    MODELOS 345RSOBK • 345RSOWW Página 22 PIEZAS DE SERVICIO Ahora se pueden hacer los pedidos de las piezas de repuesto en nuestro sitio Web. Visítenos en www.Broan.com Modelo Modelo Clave 345RSOBK 345RSOWW Descripción (Negro) (Madera curtida) 77001317 77001318 Conjunto del panel solar...
  • Página 23: Garantía

    Garantía; ambos correrán a cargo del Cliente. No obstante cualquier disposición en la presente que señale otra cosa, esta Garantía no se ampliará para Broan ni la obligará a tomar medida alguna con respecto a: (A) Productos que hayan sido modificados, alterados, instalados, usados u operados de una manera que no sea recomendada por Broan, incluyendo cualesquiera Productos en los cuales se hayan instalado piezas no fabricadas ni aprobadas por Broan;...
  • Página 24 MODELOS 345RSOBK • 345RSOWW Página 24 79040169C...

Este manual también es adecuado para:

345rsoww

Tabla de contenido