Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Battery Heater Kit
Model G0071010
Intended for HSB units 2013–Present
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
WARNING
Equipment damage. Only qualified service personnel may
install, operate, and maintain this equipment. Failure to follow
proper installation requirements could result in death, serious
injury, and equipment or property damage.
Two lead wires deliver 240V electrical power to the heater from
the N1 and N2 terminals at the customer connection panel. A
Y-harness, supplied with the heater, provides a second
connection point for an optional oil filter heater.
NOTE: The battery heater is not necessary for use with AGM-
style batteries.
IMPORTANT NOTE: The engine must be filled with synthetic
5W-30 engine oil before installing cold weather heating
accessories. Replace the engine oil if necessary before
proceeding.
NOTE: It is acceptable to operate the engine with synthetic oil
during the 25 hour break-in period if cold weather accessories
are being installed at the time of generator installation.
WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so could
result in death or serious injury.
WARNING
Skin irritation. Avoid prolonged or repeated contact with
used motor oil. Used motor oil has been shown to cause
skin cancer in laboratory animals. Thoroughly wash
exposed areas with soap and water.
Two lead wires deliver 240V electrical power to the heater from
the N1 and N2 terminals at the customer connection panel. A
Y-harness, supplied with the heater, provides a second
connection point for an optional battery heater.
Battery Heater Kit
INSTRUCTION SHEET
IMPORTANT NOTE: The engine must be filled with synthetic
5W-30 engine oil before installing cold weather heating
accessories. Replace the engine oil if necessary before
proceeding.
NOTE: It is acceptable to operate the engine with synthetic oil
during the 25 hour break-in period if cold weather accessories
are being installed at the time of generator installation.
(000100a)
(000182a)
Preparing for Installation
Automatic start-up. Disconnect normal power source
and render unit inoperable before working on unit.
Failure to do so will result in death or serious injury.
Before performing any maintenance, prevent the generator
from accidental startup:
1.
2.
3.
(000139)
NOTE: The T1, N1 and N2 fuses could be removed from the
transfer switch by an electrical contractor instead of turning off
the normal power circuit breaker.
4.
(000210)
5.
6.
WARNING
Risk of burns. Allow engine to cool before
draining oil or coolant. Failure to do so could
result in death or serious injury.
WARNING
Skin irritation. Avoid prolonged or repeated contact with
used motor oil. Used motor oil has been shown to cause
skin cancer in laboratory animals. Thoroughly wash
exposed areas with soap and water.
DANGER
Lift the lid, turn the generator OFF, and allow the unit to
cool completely.
Verify that the unit is placed in OFF mode.
Turn off normal utility power supply to the transfer switch.
• For service rated transfer switches, turn the main breaker OFF.
• For non-service-rated switches, turn power feeder breaker OFF.
With the generator shut down, remove controller fascia
(2013–2015 units) or intake side panel (2016 and newer
units), front panel, and 7.5A DC fuse.
Move the main line circuit breaker (generator disconnect)
to OFF (open).
Remove the 7.5 amp fuse from the control panel.
(000139)
(000210)
(000236)
1
Tabla de contenido
loading

Resumen de contenidos para Generac G0071010

  • Página 4: Hoja De Instrucciones

    HOJA DE INSTRUCCIONES Kit de calentador de batería Preparación para la instalación Modelo G0071010 PELIGRO Documento aplicable a las unidades HSB Configuración automática. Desconecte la fuente de alimentación vendidas desde el año 2013 hasta el año actual normal y asegúrese de que la unidad no pueda volverse operativa antes de trabajar en ella.
  • Página 5: Instalación Del Calentador De Batería (Modelos De 9 Kw)

    002916 002773 Figura 2. Retiro de la cubierta del tablero de conexiones Figura 4. Tendido de los cables del calentador (9 kW) del cliente (unidades de 2013 a 2015) Pase los cables conectores a través del ojal protector del tablero de conexiones del cliente (E). Instalación del calentador de Continúe a Conexión de cables...
  • Página 6: Conexión De Cables Conductores

    S45 W29290 Hwy. 59 Todos los derechos reservados. Waukesha, WI 53189, EE. UU. Las especificaciones están sujetas a cambios sin aviso. 1-888-GENERAC (1-888-436-3722) No se permite la reproducción bajo ninguna forma sin www.generac.com consentimiento previo escrito de Generac Power Systems, Inc.