SERVICE KIT INSTRUCTIONS
Flange
Trip Handle Assembly
Tab
Trip Arm
Tank Wall
Trip Arm Assembly
Introduction
- Please read all instructions carefully to familiarize yourself with the
required tools, materials and installation procedures.
- This document contains the latest product information available at time
of publication. Kohler reserves the right to make changes in product
characteristics, packaging or availability at any time without notice.
Installation
- Remove existing trip lever assembly (nut is a left thread nut).
- Fit trip arm assembly against tank sidewall so two tabs fit tightly
into oval hole in tank wall.
- Slide flange onto trip handle assembly, and fit flange and trip handle
into tank hole from outside of tank. As arm enters tank, slide nut
onto assembly and fingertighten. Make sure arm fits in top of trip
arm assembly hole.
- Bracket and flange must be parallel with top of tank. Make sure
flange tabs are to the sides.
- Use 7/8" open end wrench to turn nut 3/4 turn past fingertight.
- Test flush.
- If problems occur, refer to toilet homeowners guide.
A
1013959-9-
Nut
Make sure trip
arm fits in top of
assembly hole
Trip Lever Kit
1013521