FLASH FLOOD
®
EYEWASH STATION
TOOLS NEEDED
Level x 1
Cartridge Containing
Saline Solution x 1
WARNING!
• Emergency eyewash station is not for outside
use.
• The unit must be level for proper operation.
• Employees must be instructed in the use of
emergency eyewash stations.
• This unit is intended for the emergency use
of victims of eye contamination until medical
treatment is obtained.
• In all cases, the victim should seek medical
attention immediately.
• This unit must be inspected on a monthly basis.
• Use of expired solution may result in serious
personal injury.
Failure to follow and comply with all directions and
cautions stated in these instructions may result in serious
personal injury, blindness or death.
PAGE 1 OF 12
SECONDARY
Phillips Screwdriver x 1
Body and Funnel with
Perforator x 1
1-800-295-5510
uline.com
Drill x 1
9/64" Drill Bit x 1
PARTS
Mounting Template x 1
SAFETY
The ANSI Standard Z358.1-2004 requires that:
1. The unit must be positioned with the nozzle(s) not less
than 33" and no greater than 45" from the floor and
6" minimum from the wall or nearest obstruction.
2. Eyewash units must be in accessible locations that
require no more than 10 seconds to reach. The
eyewash must be located on the same level as
the hazard and the path of travel shall be free of
obstructions that may inhibit the immediate use of
the equipment. For a strong acid or a strong caustic,
the eyewash should be immediately adjacent to the
hazard.
3. Each eyewash location must be identified with a
highly visible sign positioned so the sign is visible
within the area served by the eyewash. The area
around the eyewash must be well-lit.
Para Español, vea páginas 5-8.
Pour le français, consulter les pages 9-12.
Pull Strap x 1
Mounting Screw x 2
0521 IH-7917
Tabla de contenido
loading

Resumen de contenidos para Uline FLASH FLOOD H-7917

  • Página 5: Herramientas Necesarias

    H-7917 800-295-5510 uline.mx FLASH FLOOD ESTACIÓN ® LAVAOJOS SECUNDARIA HERRAMIENTAS NECESARIAS 1 Nivel 1 Desarmador de Cruz 1 Taladro 1 Broca de 9/64" PARTES 1 Correa para Jalar 2 Tornillos de Instalación 1 Cartucho que Contiene 1 Cuerpo y Embudo con 1 Plantilla de Instalación...
  • Página 6: Instalación

    INSTALACIÓN Esta es una estación lavaojos secundaría y debe 6. Perfore los orificios piloto a través de la plantilla colocarse en un área accesible cerca del riesgo. usando el taladro de 9/64". (Vea Diagrama 3) La unidad debe estar nivelada. Diagrama 3 2.
  • Página 7: Continuación De Instalación

    CONTINUACIÓN DE INSTALACIÓN 9. Inserte dos tornillos a través de los orificios en la 12. Coloque la correa para jalar sobre las boquillas. parte posterior del cuerpo. (Vea Diagrama 6) (Vea Diagrama 9) Diagrama 6 Diagrama 9 10. Mantenga la unidad en su lugar. Inserte un 13.
  • Página 8: Funcionamiento

    4. No lavar o drenar la unidad podría resultar en solución de enjuague contaminada. NOTA: Los Cartuchos de Solución Salina contienen sal, que puede causar un residuo blanco en el cuerpo de la estación. Remueva limpiando con una tela húmeda. 800-295-5510 uline.mx PAGE 8 OF 12 0521 IH-7917...