GE SmartWater GXWH30C Manual Del Usuario
Ocultar thumbs Ver también para SmartWater GXWH30C:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Heavy Duty Water Filtration System—GXWH30C (filters not included)
I
Check with your state and local public works department
for plumbing and sanitation codes. You must follow these
guidelines as you install the Heavy Duty Water Filtration
System. Using a qualified installer is recommended.
I
Be sure the water supply conforms with the Performance
Data. If the water supply conditions are unknown, contact
your municipal water company.
This Heavy Duty Water Filtration System must be properly installed and located in accordance with the Installation Instructions
before it is used.
I
Check with your local public works department for plumbing
codes. You must follow their guides as you install the
Heavy Duty Water Filtration System.
I
Use the Heavy Duty Water Filtration System on a potable,
safe-to-drink, home COLD water supply only. The filter
cartridge will not purify water or make unsafe water safe
to drink. DO NOT use on HOT water (100
I
Protect the Heavy Duty Water Filtration System and piping
from freezing. Water freezing in the system will damage it.
I
Your Heavy Duty Water Filtration System will withstand up to
100 psi water pressure. If your house water supply pressure
is higher than 100 psi during the day (it may reach higher
levels at night), install a pressure reducing valve before the
system is installed.
REQUIRED TOOLS AND ACCESSORIES
FOR INSTALLATION
I
2 Adjustable wrenches
I
Pipe cutter or hacksaw
I
File
I
Emery paper
I
Screwdriver
I
Additional installation parts may be required:
• 2 fittings to connect household plumbing to 1" female
NPT threads on filter housing. Installation Kit available
to connect to 3/4" copper plumbing:
– GE Part/Retail Part (HDKIT)
(Not performance tested or certified by NSF.)
• UL Approved grounding clamps and 6-gauge copper
grounding wire—Installation Kit available:
– GE Part/Retail Part (HDKIT)
(Not performance tested or certified by NSF.)
GE SmartWater
INSTALLATION INSTRUCTIONS
SAFETY PRECAUTIONS
PROPER INSTALLATION
°
F max).
251B6021P002
www.GEAppliances.com
GENERAL ELECTRIC COMPANY, Appliance Park, Louisville, KY 40225
WARNING:
microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
I
It is highly recommended that a water shut-off valve be
placed directly upstream of your household filter.
I
Do not install on HOT WATER. The temperature of the
water supply to the Heavy Duty Water Filtration System
must be between the minimum of 40°F. and the maximum
of 100°F. See the Performance Data section.
I
Do not install the Heavy Duty Water Filtration System using
copper solder fittings. The heat from the soldering process
will damage the unit.
WARNING:
packaging material after installation. Small parts
remaining after installation could be a choke hazard.
I
Do not install filter in an outside location or anywhere it
will be exposed to sunlight.
• Mounting Bracket (HDBRKT)
• Teflon Tape
• Sump Wrench
– Retail Part (HDWRNCH)
– GE Parts (WX5X3002)
Optional accessories are available (Visa, MasterCard or Discover cards
accepted) by visiting our Website at www.GEAppliances.com or from
Parts and Accessories, call 800.626.2002 (U.S.) or 800.663.6060 (Canada).
CONTENTS INCLUDED WITH PRODUCT
I
Filter housing and head
I
Product literature
GXWH30C is Tested and Certified by NSF International
against ANSI/NSF Standard 42 with Cartridge FXHTC
for the reduction of Chlorine: Taste and Odor.
49-50048-6 145287 Rev. D
(03-02 JR)
1
Do not use with water that is
Discard all unused parts and

Publicidad

Tabla de contenido
loading

Resumen de contenidos para GE SmartWater GXWH30C

  • Página 9: Sistema De Filtración De Agua Extrafuerte-Gxwh30C (Filtros No Incluidos)

    Literatura del producto instalación está disponible para conectar a una tubería de cobre de 3/4″: – Partes de GE/Venta al por menor, parte (HDKIT) (Su desarrollo no ha sido probado ni ha sido certificado por la NSF.) • Abrazaderas de toma de tierra aprobadas por UL y cable de toma de tierra de cobre calibre 6.
  • Página 10: Instalación Típica

    ESPECIFICACIONES DEL CARTUCHO Cartucho FXHTC Datos del desarrollo Concentración de Requisitos de Reducción Este sistema ha sido probado de acuerdo con ANSI/NSF 42 Substancia reto entrante reducción promedio para la reducción de las substancias mostradas a continuación. La contracción de las substancias indicadas en el agua que entra Estándar 42 en el sistema fue reducida a una concentración menor o igual 2,0 mg/L ±10%...
  • Página 11 INSTRUCCIONES DE INSTALACION PASO A PASO (cont.) Seleccione la ubicación Se recomienda instalar una válvula de cierre en ambos lados del filtro. Seleccione una ubicación para el filtro que esté: Sugerimos que se utilice una ménsula de instalación. I protegida de la congelación. I que no esté...
  • Página 12: Lista De Partes

    GE • ¿Cómo la ley estatal se relaciona con esta reclamación de garantía? — Responsabilidad de parte de GE bajo esta o cualquier otra — Esta garantía le otorga derechos legales específicos, y también garantía por cualquier daño indirecto o por consecuencia de otro evento puede tener otros derechos que varían de estado a estado.

Tabla de contenido