OPERATIONAL CHECK (continued)
2B. For heaters without LED, a continuity check across the leads should
indicates a closed circuit.
3. Remove the cold source from the heater plastic body area.
4A. For heaters with LED, the LED will turn on after the temperature rises
to 65 ± 10°F.
4B. For heaters without LED, a continuity check across the leads should
indicate an open circuit after the temperature rises to 65 ± 10°F.
TROUBLESHOOTING GUIDE
CONDITION
PROBABLE CAUSE
LIGHT IS ALWAYS ON
Normal operation.
Temperature above
45°F
LIGHT IS ALWAYS ON
Thermostat is stuck open.
or HEATER IS ALWAYS OFF
Temperature below 35°F
LIGHT IS ALWAYS OFF
1. No electrical supply
Temperature Above
to the heater.
45°F
2. Defective ground.
3. Defective heater.
LIGHT IS ALWAYS OFF
Normal operation.
Temperature below
35°F
Haldex Commercial Vehicle Systems
Haldex Brake Products Corporation
10930 North Pomona Avenue
Kansas City, MO 64153-1256
Phone: (816) 891-2470
Fax: (816) 891-9447
REMEDY
No action required.
Replace heater
assembly.
1. Trace supply wire
and correct.
2. Trace and correct.
3. Replace heater
assembly.
No action required.
Haldex Limited
500 Pinebush Road, Unit 1
Cambridge, ON CANADA N1T 0A5
Phone: (519) 621-6722
Fax: (519) 621-3924
www.haldex.com
L31075 US Rev. 8/10 1M ALP
Installation
Guide
Rev. 8/10
L31075
PURE AIR DRYER
HEATER ASSEMBLY REPAIR KITS
RN60N - 12 Volt
RN60P and RN60AC - 24 Volt
TM
loading

Resumen de contenidos para Haldex RN60N

  • Página 3 SECADOR DE AIRE PURE AIR ENSAMBLAJE DEL RADIADOR LA LUZ SIEMPRE ESTÁ Funcionamiento normal. No es necesario KIT DE REPARACIONS APAGADA Temperatura hacer nada. por debajo de 1,66°C RN60N - 12 Voltios RN60P and RN60AC - 24 Voltios...
  • Página 4 Verificación de la operación El termostato del calentador se cerrará cuando la temperatura disminuye a RN60N (12 VOLTIOS) 45+/- 8F y abre cuando la temperatura aumenta a 65+/- 10 F. Para calenta- Cada Uno - Ensamblaje de radiador Con LED-12 Volt, dores con LED, el LED permanecerá...

Este manual también es adecuado para:

Rn60pRn60ac