Rheem RHMV4821SNACJA Manual De Instalación
Ocultar thumbs Ver también para RHMV4821SNACJA:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

HEAT PUMP
OUTDOOR UNIT
Contents
1.
SAFETY PRECAUTIONS ............................................................................1
1.1. IMPORTANT! Please read before starting ............................................1
1.2. Special precautions ..............................................................................1
2.
PRODUCT SPECIFICATION .......................................................................2
2.1. Installation tools ....................................................................................2
2.2. Accessories ..........................................................................................3
2.3. Pipe requirement ..................................................................................3
2.4. Power source ........................................................................................3
2.5. Electric requirement ..............................................................................3
2.6. Additional charge ..................................................................................3
2.7. Operating range ....................................................................................4
3.
INSTALLATION WORK ...............................................................................4
3.1. Selecting an installation location ..........................................................4
3.2. Installation dimensions .........................................................................4
3.3. Transporting the unit .............................................................................5
3.4. Mounting the unit ..................................................................................6
3.5. Drain installation ..................................................................................6
3.6. Removing and replacing parts ..............................................................6
3.7. Opening the knockout hole ...................................................................6
3.8. Pipe installation ....................................................................................7
3.9. Sealing test ...........................................................................................8
3.10. Vacuum process .................................................................................8
3.11. Additional charging..............................................................................8
3.12. Electrical wiring ...................................................................................9
4.
HOW TO OPERATE DISPLAY UNIT ......................................................... 11
4.1. Various setting methods ..................................................................... 11
4.2. Base heater forced off function ...........................................................12
4.3. Outdoor unit low noise operation function ..........................................12
5.
TEST RUN .................................................................................................12
5.1. TEST RUN method .............................................................................12
6.
FINISHING.................................................................................................12
6.1. Installing insulation .............................................................................12
6.2. Filling with putty ..................................................................................12
7.
CUSTOMER GUIDANCE ..........................................................................13
8.
ERROR CODE ..........................................................................................13
8.1. In the event of an error .......................................................................13
8.2. Error location display ..........................................................................13
8.3. Error code display ...............................................................................13
9.
PUMP DOWN ............................................................................................14
Installation must be performed in accordance with the requirement of NEC and CEC by
authorized personnel only.
1. SAFETY PRECAUTIONS
1.1. IMPORTANT! Please read before starting
This air conditioning system meets strict safety and operating standards.
As the installer or service person, it is an important part of your job to install or service the
system so it operates safely and effi ciently.
For safe installation and trouble-free operation, you must:
• Carefully read this instruction booklet before beginning.
• Follow each installation or repair step exactly as shown.
• Observe all local, state, and national electrical codes.
• Pay close attention to all warning and caution notices given in this manual.
WARNING:
This symbol refers to a hazard or unsafe practice which can result in
severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in
CAUTION:
personal injury and the potential for product or property damage.
• Hazard alerting symbols
9374995677-02_IM.indb 1
9374995677-02_IM.indb 1
INSTALLATION MANUAL
Electrical
Safety/alert
If Necessary, Get Help
These instructions are all you need for most installation sites and maintenance conditions.
If you require help for a special problem, contact our sales/service outlet or your certifi ed
dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for improper installation or maintenance
service, including failure to follow the instructions in this document.
1.2. Special precautions
When Wiring
ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY
A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS
SYSTEM.
• Do not supply power to the unit until all wiring and tubing are completed or reconnected
and checked.
• Highly dangerous electrical voltages are used in this system. Carefully refer to the wir-
ing diagram and these instructions when wiring. Improper connections and inadequate
earthing (grounding) can cause accidental injury or death.
• Earth (Ground) the unit following local electrical codes.
• Connect all wiring tightly. Loose wiring may cause overheating at connection points and
a possible fi re hazard.
When Transporting
Be careful when picking up and moving the indoor and outdoor units. Get a partner to
help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin
aluminum fi ns on the air conditioner can cut your fi ngers.
When Installing...
...In a Ceiling or Wall
Make sure the ceiling/wall is strong enough to hold the unit's weight. It may be necessary
to construct a strong wood or metal frame to provide added support
...In a Room
Properly insulate any tubing run inside a room to prevent "sweating" that can cause drip-
ping and water damage to walls and fl oors.
...In Moist or Uneven Locations
Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the
outdoor unit. This prevents water damage and abnormal vibration.
...In an Area with High Winds
Securely anchor the outdoor unit down with bolts and a metal frame.
Provide a suitable air baffl e.
...In a Snowy Area (for Heat Pump-type Systems)
Install the outdoor unit on a raised platform that is higher than drifting snow.
When Connecting Refrigerant Tubing
• Keep all tubing runs as short as possible.
• Use the fl are method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces of the fl are and union tubes before
connecting them, then tighten the nut with a torque wrench for a leak-free connection.
• Check carefully for leaks before opening the refrigerant valves.
NOTE:
Depending on the system type, liquid and gas lines may be either narrow or wide. There-
fore, to avoid confusion the refrigerant tubing for your particular model is specifi ed as
either "small" or "large" rather than as "liquid" or "gas".
When Servicing
• Turn the power OFF at the main circuit breaker panel before opening the unit to check
or repair electrical parts and wiring.
• Keep your fi ngers and clothing away from any moving parts.
• Clean up the site after you fi nish, remembering to check that no metal scraps or bits of
wiring have been left inside the unit being serviced.
• After installation, explain correct operation to the customer, using the operating manual.
• Please pass this Installation manual together with the Operating manual to the customer.
Please ask the customer to keep the Operating manual and Installation manual at hand
for future reference during the moving or repair of the main unit.
PART No. 9374995677-02
For authorized service personnel only.
.
En-1
12/9/2020 3:41:47 PM
12/9/2020 3:41:47 PM
Tabla de contenido
loading

Resumen de contenidos para Rheem RHMV4821SNACJA

  • Página 29: Bomba De Calor Unidad Exterior

    MANUAL DE INSTALACIÓN BOMBA DE CALOR UNIDAD EXTERIOR N.º DE PIEZA 9374995677-02 Únicamente para personal de servicio autorizado. Eléctrico Seguridad/alerta Si fuese necesario, consiga ayuda Estas instrucciones son todo lo que necesita para la mayoría de sitios de instalación y condiciones de mantenimiento.
  • Página 30: Especificaciones Del Producto

    ADVERTENCIA ATENCIÓN • Para evitar una descarga eléctrica, nunca toque los componentes eléctricos poco • Esta unidad debe instalarla personal califi cado con una certifi cación de capacidad después de haber apagado la alimentación eléctrica. Después de apagar la energía, de manejo de fl...
  • Página 31: Accesorios

    Grosores de las tuberías de cobre recocido 2.4. Fuente de alimentación Diámetro nominal (pulg.) Diámetro exterior (mm) Grosor [pulg.(mm)] 6,35 ADVERTENCIA 9,52 0,032 (0,80) • Use siempre un circuito de ramal especial e instale un receptáculo especial para 12,70 suministrar energía al acondicionador de aire del cuarto. •...
  • Página 32: Rango De Operación

    Decida junto con el cliente el lugar de instalación, teniendo en cuenta los criterios que 2.7. Rango de operación fi guran a continuación: (1) Instale la unidad exterior en un lugar que pueda soportar el peso de la unidad y las vibraciones y que permita una instalación horizontal.
  • Página 33: Instalación De Varias Unidades Exteriores

    Cuando hay una obstrucción en el espacio superior [ Unidad: pulg. (mm) ] 3.2.3. Instalaciones de unidades exteriores de fi las múltiples [ Unidad: pulg. (mm) ] (1) Obstáculos en la parte posterior y encima (2) Obstáculos en la parte posterior, encima * No se recomienda realizar los siguientes ajustes en caso de refrigerar mediante una y laterales temperatura exterior baja.
  • Página 34: Montaje De La Unidad

    [Unidad: pulg. (mm) ] 3.4. Montaje de la unidad Orificio de montaje del tapón de drenaje ×7 3 (76) • Instale la unidad interior sin inclinación. (dentro de los 3 grados) Orificio de montaje de la • Coloque 4 pernos de anclaje en los puntos indicados por las fl echas de la fi gura. tubería de desagüe 1-15/16 (50) •...
  • Página 35: Instalación De Tuberías

    ■ Doblado de tuberías Fig. A ATENCIÓN Panel de • Para evitar que se rompa la tubería, evite los ángulos muy cerrados. Doble la servicio tubería con un radio de curvatura de 4 pulg. (100 mm) o superior. • Si la tubería se dobla repetidamente por el mismo punto, se romperá. •...
  • Página 36: Prueba De Estanqueidad

    Procedimiento de evacuación 3.9. Prueba de estanqueidad (1) Retire los tapones de la tubería de gas y de líquido y compruebe que las válvulas están cerradas. (2) Retire el tapón de carga. ADVERTENCIA (3) Conecte la bomba de vacío y el manómetro a la manguera de carga y conéctela al puerto de carga.
  • Página 37: Inspección De Fuga De Gas

    ■ Inspección de fuga de gas ATENCIÓN ATENCIÓN • La capacidad de la fuente de alimentación principal es para el propio acondicionador de aire y no incluye el uso de otros dispositivos al mismo tiempo. • Conecte los cables de alimentación en una secuencia de fase positiva. Si hay una Después de conectar la tubería, revise todas las juntas en busca de fugas de gas con conexión de pérdida de fase, la unidad no funcionará...
  • Página 38: Preparación Del Cable

    ■ Cómo conectar el cableado al terminal ■ Preparación del cable Precaución durante el cableado La longitud del cable de tierra debe ser superior a la del resto de cables. NOTA: Para utilizar un cable sellado • Cuando retire el revestimiento de un cable conductor, utilice siempre una herramienta especial como un alicate pelacables.
  • Página 39: Cómo Operar La Unidad De Visualización

    ■ Instalación de conductos 4. 1. 1. Método de confi guración (1) Asegúrese de desconectar la fuente de alimentación o de apagar el disyuntor. Conexión delantera Conexión lateral Conexión posterior (2) Cambie la confi guración del interruptor DIP de acuerdo con la confi guración requerida.
  • Página 40: Función De Apagado Forzado Del Calefactor Base

    (3) Presione el interruptor “TEST RUN” (CICLO DE PRUEBA) por más de 3 segundos. 4.2. Función de apagado forzado del calefactor base El LED de ENERGÍA / MODO destellará una vez. Modelo 1736 TEST RUN Es posible cortar la alimentación del calefactor base si se modifi ca la confi...
  • Página 41: Asesoría Para El Cliente

    Modo de visualización 7. ASESORÍA PARA EL CLIENTE LED encendido: Explique al cliente lo siguiente de acuerdo con el manual de operación: (1) Método de arranque y paro, cambio de operación, ajuste de temperatura, LED apagado: temporizador, ajuste de fl ujo de aire y demás operaciones de la unidad de control remoto.
  • Página 42: Evacuación

    NOTAS: 9. EVACUACIÓN • Si la evacuación no se detiene al presionar el interruptor como en el paso (6), se detendrá automáticamente después de 15 minutos y el LED se encenderá como se indica a continuación. Si la evacuación se completa, desconecte la alimentación ADVERTENCIA eléctrica o apague el disyuntor.
  • Página 43 9374995677-02_IM.indb 15 9374995677-02_IM.indb 15 12/9/2020 3:41:51 PM 12/9/2020 3:41:51 PM...
  • Página 44 9374995677-02_IM.indb 16 9374995677-02_IM.indb 16 12/9/2020 3:41:51 PM 12/9/2020 3:41:51 PM...

Este manual también es adecuado para:

Rhmv3021snacjaRp1730hjvxaRhmv2421mnacjaRhmv3621mnacja

Tabla de contenido