HEAVYWEIGHT
Always Read All Product Literature BEFORE installing product.
https://www.warn.com/manuals/index.jsp
• Always position fairlead with warning readily visible on top.
• Always use class 8.8 metric (grade 5) or better hardware.
• Never weld mounting bolts.
• Never use bolts that are too long.
• Always con rm required bolt length to ensure proper thread engagement.
• Always complete the winch installation and hook attachment before installing the wiring.
Item Qty
Description
A
4
7/16" (11.1 mm)
B
4
7/16-14 X 1 1/2"
C
2
7/16-14 X 1 3/4"
D
6
7/16" (11.1 mm)
A
B
C
50-55 ft. lbs. (68-75Nm)
WARNING
Mounting
Plate Thickness
Bolt Length
5/16" (8 mm)
1.5" (40 mm)
3/8" (10 mm)
1.5" (40 mm)
1/2" (13 mm)
1.75" (45 mm)
Item Qty
Description
A
4
7/16" (11.1 mm)
B
2
7/16-14 X 1 1/2"
C
4
7/16-14 X 1 3/4"
D
6
7/16" (11.1 mm)
D
A
B
C
Item Qty
A
1
Control Pack
B
1
7/16-14 x 1"
• Always remove jewelry and wear eye protection when making battery connections.
• Never route electrical cables across sharp edges.
• Never route electrical cables near parts that get hot.
• Never route electrical cables over battery terminals.
• Never route electrical cables through or near moving parts.
• Always insulate and protect all exposed wiring and electrical terminals.
• Always place the supplied terminal boots on wires and terminals.
16.5 Ti
Only
D
Ground (Black) Cable
98973A0
Control Pack Mounting
16.5Ti
Description
Item Qty
A
1
B
1
C
1
B
D
2
A
Wiring
WARNING
A
F1
F2
Power (Red) Cable
M12/M15
Description
Control Pack
7/16-14 x 1"
Bracket
M6 -1.0
A
B
C
D
98973A0