Motion Sensor
Light Control
Model SL-5597
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Dual Brite™ Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Lamp
Holders
Cover
Plate
Light Control
Mounting Strap
Mounting Bolt
Plastic Hanger
Rubber Plug
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Override, the control must
be wired through a switch.
• Some codes require installation by a qualified
electrician.
• This product is intended for use with a junction box
marked for use in wet locations.
© 2003 DESA Specialty Products™
6 Screws
(3 sizes included)
Gasket
Sensor
2 Wire
Connectors
2 Lamps
(installed)
OPERATION
Mode:
On-Time:
Test
5 Sec
Auto
1, 5, 20 min.
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
the circuitry to calibrate.
Put ON-TIME switch
on the sensor bottom
to TEST and the Dual
Brite™ switch OFF.
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 20 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
Dual Brite™ TIMER
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light
turns on full bright for the ON-TIME (1,5 or 20 minutes)
then returns to dim mode.
Works:
Day
x
1
/
minutes for
2
TEST
DUAL BRITE™
ON-TIME
Off 3 6 Dusk to
TEST 1 5 20
Dawn
AUTO
ON-TIME
TEST 1 5 20
1 Second OFF
then ...
... back on.
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
595-5679-06
Night
x
x
x
Tabla de contenido
loading

Resumen de contenidos para Heath Zenith Dual Brite SL-5597

  • Página 5: Detector De Movimiento Y Control De Luz Dual Brite

    Cuando lo prenda por primera vez espere 1 minutos hasta que el circuito se calibre. Para PRUEBA: Detector de Movimiento Ponga el interruptor de ON-TIME DUAL BRITE™ tiempo (ON-TIME), al y Control de Luz fondo del detector, en la posición de prueba Off 3 6 Dusk to TEST 1 5 20 Dual Brite™...
  • Página 6: Instalacion

    ❒ Quite el aparato de luz existente. INSTALACION ❒ Instale la lámina de montaje a la caja de empalme Para una fácil instalación escoja una luz con un usando tornillos apropiados para la caja de empalme. interruptor de pared. ❒ Se puede usar el colgador plástico para sostener el CUIDADO: Para evitar los peligros de incendio aparato mientras se instala el cableado.
  • Página 7: Prueba Y Ajuste

    ❒ Afloje el tornillo de la grampa PRUEBA Y AJUSTE Tornillo en la unión esférica del de- de la ❒ Prenda el cortacircuitos y el interruptor de luz. tector y gire suavemente el Grampa detector para apuntar. NOTA: El detector tiene un período de cerca de 1 ❒...
  • Página 8: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La luz no se 1. El interruptor de luz está apagado. La luz se 1. Un faro está colocado demasiado cerca enciende. 2. El faro está flojo o fundido. queda al detector o apunta a objetos cercanos 3.

Tabla de contenido