Operating Instructions and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Sewage Pump
Description
A sewage system consists of a pump,
control switch, and a ba sin for use in
ap pli ca tions where less than six toilets
(units) are dis charged into the basin.
The sys tem is generally con trolled by a
float switch with a plug-in-plug which
accepts the pump plug and in turn
plugs into a 115 volt outlet.
The float switch is a wide angle
differential switch that rises with the
liquid level and turns the pump on.
As the liquid level decreases the float
lowers and turns the pump off. This
pump is in tend ed for use in do mes tic
sewage lift stations. It is suitable for
pumping sewage, effluent, wastewater,
groundwater and other non ex plo sive,
non cor ro sive liquids with up to 2 inch
solids.
Specifications
Power supply requirements .............. 115V, 60 hz
Circuit requirements .......................... 15 amps (min)
Motor duty ......................................... Intermittent
Motor ................................................. 115V, 1 Phase, 1725 RPM
Horsepower ....................................... 4/10 (BSEL40); 1/2 (BSEL50)
Motor full load .................................. 12 amps
Liquid temperature range ................. 40º F to 120º F
Max. operating position .................... 45º from vertical
Dimensions ......................................... 13-1/2 inch x 11 inch
Intake ................................................. 2 inch
Discharge ............................................ 2 inch NPT female, 3 inch
Cut-in level (factory set) .................... 18 inch
Cut-out level (factory set) ................. 10 inch
Differential ......................................... 8 inch
Switch ................................................. 90º wide angle
Power cord ......................................... 16 gauge 3 conductor
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2008 Blue Angel™ Pumps
unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
NPT male
mechanical tether switch
w/plug
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.blueangelpumps.com
BSEL40, BSEL40M, BSEL40T-2,
BSEL50, BSEL50M
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
information, that if not followed, may
cause damage to equipment.
General Safety Information
CALIfORNIA PROPOSITION 65
Danger indicates
an imminently
chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
Construction
Motor body material ............Cold rolled steel
Motor housing ......................Glass reinforced
Volute ....................................Glass reinforced ABS
Impeller .................................Glass reinforced PBT
Seal plate ..............................Cast Iron
Shaft seal ...............................End faced mechanical
Performance
GALLONS PER hOuR AT TOTAL hEAD IN fEET
Model
BSEL40
BSEL50
Warning indicates
a potentially
Caution indicates
a potentially
Notice indicates
important
This product or its
power cord contains
polypropylene
10
15
3700
1350
6420
4200
1500
330004-002 12/08
200
0

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Blue Angel BSEL40

  • Página 13: Descripción

    Ciclo del motor ......Intermitente Caja espiral ......Plástico ABS reforzado Motor ........... 115V, 1 fase, 1725 RPM con vidrio Caballos de fuerza ...... 4/10 (BSEL40) 1/2 (BSEL50) Impulsor ........Plástico PBT reforzado Motor (Cap. máx.) ....... 12 amperios con vidrio Temp. de funcionamiento ..4ºC a 49ºC (40º F a 120º F) Sello de la placa ....Hierro colado...
  • Página 14 Manual de Instrucciones de Operación y Piezas Informaciones Generales de Antes de cada uso, inspeccione ¡Peligro las mangueras, para ver si están Seguridad (Continuación) de choque eléctrico! Nunca dañadas o desgastados y cerciórese conecte los cables verdes o GENERALES DE SEGuRIDAD de que las conexiones estén bien verde con rayas amarillas, a apretadas.
  • Página 15: Instalación

    BSEL40, BSEL40M, BSEL40T-2, BSEL50, BSEL50M Informaciones Generales de Mantenimiento Enrosque la tubería de descarga o el niple en el orificio de descarga Seguridad (Continuación) Siempre desconecte de la unidad. 13. Es altamente recomendable que el cordón eléctrico Si usa una válvula de chequeo, en...
  • Página 16: Guía De Diagnóstico De Averías

    Manual de Instrucciones de Operación y Piezas Mantenimiento Coloque la bomba en un Limpie bien el orificio de entrada de sitio adecuado para limpiarla la bomba y la voluta. (Continuación) completamente. Quítele todos los Esta bomba Chequée la bomba periódicamente residuos e impurezas a la bomba.
  • Página 17: Lista De Partes De Reparación

    17317-001 Caja espiral (incluye 6 tornillos) 23272-001 Aceite dieléctrico 55932 2.2 pints Juego de interruptor mecánico (BSEL40, BSEL40M, BSEL50, BSEL50M) 60022-001 Juego de interruptor mecánico (BSEL40T-2) 56836-002 Tapón de aceite 37303-001 Tornillo de #8 - 16 x 25,4 mm (1 inch)
  • Página 18: Registro De Servicios

    Garantía Limitada Durante un año a partir de la fecha de compra, Blue Angel reparará o reemplazará, según lo consideren adecuadon, cualquier pieza de esta bomba para sumideros (“Producto”) que el comprador original envie a reparación y los empleados o representantes autorizados de Blue Angel determinen que están defectuosos debido a problemas de materiales o manufactura.