Descargar Imprimir esta página

Cree C-Lite Instrucciones De Instalación

Led de panel plano con respaldo de emergencia

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

INSTALLATION INSTRUCTIONS
C-LITE LED Flat Panel With
Emergency Back-up
1x4
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
Caution - Risk of Fire.
Attention - Risque D'incendie
3.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou votre
code électrique local. Si vous n'êtes pas familier avec ces
codes et ces exigences, veuillez contacter un électricien
qualifié.
4.
Suitable for damp locations.
Convient aux emplacements humides.
5.
Min 90°C supply conductors.
Les fils d'alimentation 90°C min.
2x2
2x4
http://lighting.cree.com/warranty
Document:
LPN00553X0001A0
Created By:
TMT
6.
Inherently protected.
Protection inherente.
7.
Type IC. Vapor barrier must be suitable for 90°C.
Type IC. Le pare-vapeur doit convenir pour 90°C.
8.
For use in Non-fire rated installations only
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
INSTALLATION
1.
Locate desired fixture location in ceiling grid.
2.
Remove existing ceiling panel at chosen location. Remove
adjacent ceiling panel to allow for wiring access from above.
3.
Place fixture into T-bar ceiling grid. Bend clips on top of fixture up
and rotate out to engage with T-bar support grid. See Figure 1.
Secure fixture to grid in compliance with state and local codes.
4.
Remove screw on driver wiring chamber and remove cover. Set
screw and cover aside to be reinstalled later.
5.
Remove appropriate 1/2" knockout(s) to allow for entry of supply
wiring into wiring chamber.
6.
Make wiring connections per the Fixture Wiring section.
NOTE:
• Terminal blocks in driver wiring chamber will accommodate
12-20 AWG solid or stranded leads for supply and 18-24
AWG solid or stranded leads for dimming.
7.
Reattach cover of wiring chamber with screw that was removed in
Step 4 above.
8.
Replace adjacent ceiling panel removed in Step 2.
FIGURE 1
|
866.924.3645
Date
98-1-2019

Publicidad

loading

Resumen de contenidos para Cree C-Lite

  • Página 4: Instalación

    LPN00553X0001A0 Fecha 01-08-2019 INSTRUCCIONES DE INSTALACIÓN Creado por: C-LITE LED de panel plano con respaldo de emergencia Protección inherente. Protection inherente. Tipo IC. La barrera de vapor debe ser adecuada para 90 °C. Tipo IC. Le pare-vapeur doit convenir pour 90°C.
  • Página 5 01-08-2019 INSTRUCCIONES DE INSTALACIÓN Creado por: C-LITE LED de panel plano con respaldo de emergencia CABLEADO DE LA LUMINARIA NOTA: La luminaria está equipada con una unidad de voltaje universal de 120 a 277 V. Si se conecta la luminaria con un voltaje fuera del rango de 120 a 277 V puede provocar daños a la luminaria y/o operación incorrecta de la misma.
  • Página 6 LPN00553X0001A0 Fecha 01-08-2019 INSTRUCCIONES DE INSTALACIÓN Creado por: C-LITE LED de panel plano con respaldo de emergencia AVISO de Clase B DE LA FCC VERIFICACIÓN DE LA UNIDAD DE EMERGENCIA PRECAUCIÓN: Los cambios o las modifi caciones no aprobados NOTA: Para prueba a corto plazo de la función de emergencia, la podrían anular su autoridad para usar este equipo.